Live working - Electrical insulating matting
Introduction: This document has been prepared according to the requirements of IEC 61477 where applicable. The product covered by this document may can have an impact on the environment during some or all stages of its life cycle. These impacts can range from slight to significant, be of short-term or long-term, and occur at the global, regional or local level. Except for a disposal statement in the instructions for use, this document does not include requirements and test provisions for the manufacturers of the product, or recommendations to the users of the product for environmental improvement. However, all parties intervening in its design, manufacture, packaging, distribution, use, maintenance, repair, reuse, recovery and disposal are invited to take account of environmental considerations.
Scope: This document is applicable to electrical insulating matting made of elastomer flexible insulating material for use as a floor covering for of the surface on which the worker is positioned and for worker´s electrical protection of workers on electrical installations up to 36 000 V AC for AC use or 36 000 V AC and 54 000 V DC for AC/DC use. NOTE 1 For a.c. electrical classification, as well as d.c. use, see 4.2. NOTE 2 This document gives a.c. test provisions. There is limited history for use in d.c. applications. NOTE 3 See Annex A for suggested maximum voltage use. NOTE 1 The electric potential of the surface on which the worker is positioned is usually that of earth. NOTE 2 See 4.2 for maximum use voltage. NOTE 3 DC only rated matting is not specified in this document. NOTE 4 This document does not cover the use of insulating blankets (see IEC 61112)
Contents:
- FOREWORD
- INTRODUCTION
- Scope