Ultrasonics – Power measurement – Radiation force balances and performance requirements
Introduction: A number of measuring methods exist for the determination of the total emitted power of ultrasonic transducers ([1], [2], [3] 1, see also Annex C). The purpose of this International Standard is to establish standard methods of measurement of ultrasonic power in liquids in the lower megahertz frequency range based on the measurement of the radiation force using a gravimetric balance. The great advantage of radiation force measurements is that a value for the total radiated power is obtained without the need to integrate field data over the cross- section of the radiated sound beam. This standard identifies the sources of errors and describes a systematic step-by-step procedure to assess overall measurement uncertainty as well as the precautions that should be undertaken and uncertainties that should be taken into account while performing power measurements. Basic safety requirements for ultrasonic physiotherapy devices are identified in IEC 60601-2-5 and make reference to IEC 61689, which specifies the need for acoustic power measurements with an uncertainty better than ± 15 % at a level of confidence of 95 %. Considering the usual degradation of accuracy in the practical application of this standard, reference measurement methods need to be established with uncertainties better than ± 7 %. Ultrasonic diagnostic device declaration requirements including acoustic power are specified in other IEC standards, as for example in IEC 61157. The measurement of acoustic power accuratel
Scope: This International Standard specifies a method of determining the total emitted acoustic power of ultrasonic transducers based on the use of a radiation force balance; establishes general principles for the use of radiation force balances in which an obstacle (target) intercepts the sound field to be measured; establishes limitations of the radiation force method related to cavitation and temperature rise; establishes quantitative limitations of the radiation force method in relation to diverging and focused beams; provides information on estimating the acoustic power for diverging and focused beams using the radiation force method; provides information on assessment of overall measurement uncertainties. This International Standard is applicable to: the measurement of ultrasonic power up to 1 W based on the use of a radiation force balance in the frequency range from 0,5 MHz to 25 MHz; the measurement of ultrasonic power up to 20 W based on the use of a radiation force balance in the frequency range 0,75 MHz to 5 MHz; the measurement of total ultrasonic power in well-collimated, diverging and focused ultrasonic fields; the use of radiation force balances of the gravimetric type or force feedback type. (See also Clause A.1) NOTE 1 A focused beam is converging in the pre-focal range and diverging beyond focus. NOTE 2 Ultrasonic power measurement in the high intensity therapeutic ultrasound (HITU) range, i.e. beyond 1 W or 20 W, respectively, is dealt with in the future IEC 62555.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 5.10 Calibration
- 7.10 Water temperature
- 7.11 Ultrasonic attenuation and acoustic streaming
- 7.12 Foil properties
- 7.13 Finite target size
- 7.14 Plane-wave assumption
- 7.15 Scanning influence
- 7.16 Environmental influences
- 7.17 Excitation voltage measurement
- 7.18 Ultrasonic transducer temperature