IEC 61223-2-11-1999 PDF

IEC 61223-2-11-1999 PDF

Evaluation and Routine Testing in Medical Imaging Departments - Part 2-11: Constancy Tests - Equipment for General Direct Radiography

$163.93 $327.86 -50%
Product Code: IEC 61223-2-11
Stock In Stock
Edition: 1.0
Published: 09/1999
Number of Pages: 46
File Size: 1 file, 231 Bytes

Available Options

Product Description

Evaluation and Routine Testing in Medical Imaging Departments - Part 2-11: Constancy Tests - Equipment for General Direct Radiography

Scope: This part of IEC 61223 applies to those components of X-RAY EQUIPMENT which generate, influence the propagation of, and detect X-RADIATION; and process, present and store radiographic information in RADIOLOGICAL INSTALLATIONS with diagnostic X-ray systems using RADIOGRAPHIC FILM in DIRECT RADIOGRAPHY. This standard is a part of a series of Particular Publications (international standards and technical reports), which define methods of testing the constancy of operation of various subsystems of diagnostic X-RAY EQUIPMENT. This standard does not apply to equipment for special applications such as mammographic X-RAY EQUIPMENT or dental X-RAY EQUIPMENT; see complete list of all parts 2 of IEC 61223 in the foreword. This standard gives methods of tests for the constancy of properties of diagnostic X-RAY EQUIPMENT as described in IEC 61223-1 (see clause 2). This part of IEC 61223 is designed to be applicable to equipment for general direct radiography without digital imaging devices. 1.2 Object This standard defines the essential parameters which describe or affect the performance of the above components of X-RAY EQUIPMENT; methods of checking that variations in measured quantities related to those parameters are within acceptable limits, in order to maintain adequate standards of imaging whilst reducing unnecessary IRRADIATION of the PATIENT. The methods are based upon assessments of RADIOGRAMS of appropriate TEST DEVICES. The purpose of the methods is to establish a reference level of performance when such equipment is accepted; to detect and verify any significant variation in performance which may require corrective action. Because RADIOLOGICAL INSTALLATIONS differ widely from each other, it is not possible in this standard to specify target values and tolerances for the parameters which would be generally applicable as criteria of acceptable performance. Guidance is given, however, as to the degree of variation in single measurements which might require appropriate action. – 6 – 61223-2-11 © IEC:1999(E) This standard does not deal with aspects of mechanical and electrical safety; checks of the effectiveness of the direct means of protection against X-RADIATION; o

Contents:

  • FOREWORD
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61223-2-11-1999 PDF

IEC 61223-2-11-1999 PDF

$163.93 $327.86