Evaluation and routine testing in medical imaging departments-Part 3-2: Acceptance tests-Imaging performance of mammographic X-ray equipment

$239.59 $479.18 -50%
Product Code: IEC 61223-3-2
Stock In Stock
Edition: 2.0
Published: 07/2007
Number of Pages: 128
File Size: 1 file, 904 Bytes

Available Options

Product Description

Evaluation and routine testing in medical imaging departments – Part 3-2: Acceptance tests – Imaging performance of mammographic X-ray equipment

Introduction: This standard is part of a series of International Standards which give methods of acceptance testing and constancy testing for diagnostic X-RAY EQUIPMENT. This second edition of the particular standard for the ACCEPTANCE TEST of mammographic X- RAY EQUIPMENT describes test methods for EQUIPMENT using RADIOGRAPHIC FILMS, EQUIPMENT using storage phosphor plates, EQUIPMENT using integrated digital X-RAY IMAGE RECEPTORS, and MAMMOGRAPHIC STEREOTACTIC DEVICES.

Scope: This part of IEC 61223 applies to the effectiveness of mammographic X-RAY EQUIPMENT, with respect to image quality and dose, in combination with aspects of EQUIPMENT safety. This standard applies to mammographic X-RAY EQUIPMENT and MAMMOGRAPHIC STEREOTACTIC DEVICES. The tests described in this standard require the quality and performance of the X-RAY IMAGE RECEPTORS to be assured prior to the acceptance testing when they are not an integral part of the mammographic X-RAY EQUIPMENT. This includes RADIOGRAPHIC FILMS, INTENSIFYING SCREENS, RADIOGRAPHIC CASSETTES, storage phosphor plates and ASSOCIATED EQUIPMENT such as film processors or storage phosphor plate readers, IMAGE DISPLAY DEVICES and HARD COPY CAMERAS. For testing RADIOGRAPHIC CASSETTES and INTENSIFYING SCREENS, this standard makes reference to ISO 4090. Sensitivity and contrast for the screen-film image receptors are considered to be stated according to ISO 9236-3. NOTE Currently there exists no IEC standard for acceptance testing of HARD COPY CAMERAS or IMAGE DISPLAY DEVICES. By the measurements described in this standard, data for AVERAGE GLANDULAR DOSE calculation can be determined. When the results of the ACCEPTANCE TEST are in compliance with the expected values, the baseline values for the subsequent CONSTANCY TESTS are established. This part of IEC 61223 defines a) the essential parameters which describe the performance of the above-mentioned mammographic X-RAY EQUIPMENT with regard to image quality and dose; and b) the methods of testing whether measured quantities related to those parameters comply with specified tolerances. These methods mainly rely on non-invasive measurements that use appropriate test EQUIPMENT and are performed during or after the installation. Signed statements covering steps in the installation procedure can be used as part of the ACCEPTANCE TEST. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance. This concept is described in 4.1. – 8 – 61223-3-2 © IEC:2007 This standard does not in itself specify limiting values or tolerances for the parameters under investigation. A difficulty may arise with regard to the

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 5.10 Breast COMPRESSION DEVICE
  • 5.11 Uniformity
  • 5.12 Dynamic range of mammographic X-RAY EQUIPMENT using digital X-ray image
  • 5.13 Spatial resolution
  • 5.14 LOW CONTRAST DETECTABILITY
  • 5.15 Entrance surface AIR KERMA
  • 5.16 Biopsy needle positioning accuracy of MAMMOGRAPHIC STEREOTACTIC DEVICES