Compression and mechanical connectors for power cables - Part 1-2: Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on insulated conductors

$275.00 $550.00 -50%
Product Code: IEC 61238-1-2
Stock In Stock
Edition: 1.0
Published: 05/08/2018
Number of Pages: 112
File Size: 1 file, 2 Bytes

Available Options

Product Description

Compression and mechanical connectors for power cables - Part 1-2: Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on insulated conductors

Introduction: The IEC 61238 series has been divided into the following parts: Part 1-1: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on non-insulated conductors Part 1-2: Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on insulated conductors Part 1-3: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) tested on non-insulated conductors This Part 1-2 of IEC 61238-1 deals with type tests for insulation piercing connectors for use on copper or aluminium conductors of power cables for rated voltages up to 1 kV (Um = 1,2 kV). When a design of connector meets the requirements of this document, then it is expected that in service: a) the resistance of the connection will remain stable within specified limits; b) the temperature of the connector will be of the same order or less than that of the insulated conductor during current heating; c) if the intended use demands it, application of short-circuit currents will not affect a) and b); d) independently from the electrical performance, conforming axial tensile strength will ensure an acceptable mechanical performance for the connections to the cable conductors, when applicable. It should be stressed that, although the object of the electrical and mechanical tests s

Scope: This part of IEC 61238 applies to insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV), for example according to IEC 60502-1 or other buried cables and cables installed in buildings, having a) conductors complying with IEC 60228 having nominal cross-sectional areas between 2,5 mm2 and 300 mm2 for copper and between 16 mm2 and 500 mm2 for aluminium, b) a maximum continuous cable temperature not exceeding the insulation material properties. This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact. The object of this document is to define the type test methods and requirements, which apply to insulation piercing connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused insulated conductors.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope