Ultrasonics - Hand-Held Probe Doppler Foetal Heartbeat Detectors - Performance Requirements and Methods of Measurement and Reporting

$132.41 $264.81 -50%
Product Code: IEC 61266
Stock In Stock
Edition: 1.0
Published: 12/1994
Number of Pages: 64
File Size: 1 file, 2 Bytes

Available Options

Product Description

Ultrasonics - Hand-Held Probe Doppler Foetal Heartbeat Detectors - Performance Requirements and Methods of Measurement and Reporting

Introduction: Hand-held ultrasonic Doppler foetal heartbeat detectors are widely used for monitoring foetal heartbeat during pregnancy. They normally operate at frequencies of circa 2 MHz, and consist of an ultrasonic transducer acoustically coupled to the maternal abdomen and associated electronics. A beam of ultrasound is directed by the operator to impinge on the foetal heart and a small fraction of the incident ultrasound is reflected from the moving su rfaces of the heart. This ultrasound is subject to a frequency shift as a result of the Doppler effect. It is then detected by a receiving transducer. Signal processing separates the low-frequency signals associated with the foetal heartbeat from the high-frequency ultrasonic oscillations and amplifies them for audio detection. This International Standard, IEC 1266, specifies methods of evaluating the performance of ultrasonic foetal heartbeat detectors and, in particular, specifies a method of determining the sensitivity of the system to the detection of a moving target. Foetal Doppler monitoring devices use a flat probe strapped to the patient and work on a principle similar to that of hand-held foetal heartbeat detectors but are not covered by this standard. The reason is that monitoring devices require a wide angle of view which is often realised by using a multi-element transducer. This makes the method of operation of foetal Doppler monitors much more complex than that of hand-held foetal heartbeat detec- tors which use a narrow b

Scope: This International Standard IEC 1266 establishes: methods of measurement of performance of a complete ultrasonic hand-held Dop- pler foetal heartbeat detector (hereinafter referred to as "equipment"); requirements for the performance of equipment; requirements for the reporting of the performance of existing equipment; requirements for the declaration by manufacturers in accompanying literature of aspects of the performance of equipment. This International Standard is applicable to ultrasonic Doppler foetal heartbeat detectors which generate a single ultrasound beam and consist of a hand-held probe which is applied to the maternal abdomen to obtain information on foetal heart activity by means of the Doppler method using continuous wave (c.w.) or quasi-continuous wave ultrasound. This standard, however, currently does not cover the continuous monitoring devices which generate more than one ultrasound beam and are usually of the type utilising a similar principle of operation but using a flat probe strapped to the patient. This International Standard is not an equipment design standard.

Contents:

  • FOREWORD
  • INTRODUCTION
  • 1 Scope
  • 2 Normative references
  • 3 Definitions
  • 4 List of symbols
  • 5 Configuration
  • 6 Pe rformance
  • 6.1 Acoustic working frequency
  • 7 Safety
  • 8 Tests
  • 8.1 Acoustic working frequency
  • 8.2 Output power
  • 8.3 Spatial-peak temporal-peak acoustic pressure
  • 8.4 Effective area of the ultrasonic transducer active element
  • 8.5 Overall sensitivity
  • 9 Preferred method for reporting pe rformance of existing equipment
  • 10 Specifications for labelling
  • 11 Sampling