Fibre optic communication subsystem test procedures - Part 4-4: Cable plants and links - Polarization mode dispersion measurement for installed links
Introduction: Polarization mode dispersion (PMD) is a statistical parameter. The reproducibility of measurements depends on the particular method, but is limited also by the PMD level of the link and the accessible wavelength range. Gisin [1]1 derived a theoretical limit to this reproducibility independent of the measurement method by assuming ideal measurement conditions. Originally, the principles of IEC 61280-4-4:2006 were closely aligned with those of IEC 607931-48:2003 on optical fibre and optical fibre cable test method, which focuses on aspects related to the measurement of factory lengths. However, IEC 60793-1-48:2007 removed some of the test methods that are no longer of interest to fibre and cable manufacturers. These have been retained as informative Annexes D, E, and F in this document, and a new test method G has been added. This document also updates test methods A, B and C and adds more information applicable to testing of installed cabling. NOTE 1 Test methods for factory lengths of optical fibres and optical fibre cables are given in IEC 60793-1-48. NOTE 2 Test methods for optical amplifiers (OAs) are given in IEC 61290-11-1 and IEC 61290-11-2. NOTE 3 Test methods for passive optical components are given in IEC 61300-3-32. NOTE 4 Guidelines for the calculation of PMD for links that include components such as dispersion compensators or optical amplifiers are given in IEC TR 61282-3. NOTE 5 Further general guidance on PMD measurements and background theory is contained in IE
Scope: This part of IEC 61280 provides uniform methods of measuring polarization mode dispersion (PMD) of single-mode installed links. An installed link is the optical path between transmitter and receiver, or a portion of that optical path. These measurements can be used to assess the suitability of a given link for high bit rate applications, or to provide insight on the relationships of various related transmission attributes. This document focuses on the measurement methods and requirements for measuring long lengths of installed cabling that can also include other optical elements, such as splices, connectors, amplifiers, chromatic dispersion compensating modules, dense wavelength division multiplexing or multiplexer (DWDM) components, multiplexers, wavelength selective switches, re-configurable optical add drop multiplexer (ROADMS). This document focuses on the apparatus, procedures, and calculations needed to complete measurements. IEC TR 61282-9 explains the theory behind the test methods.
Contents:
- FOREWORD
- INTRODUCTION
- Scope