IEC 61340-4-4-2018 PDF

IEC 61340-4-4-2018 PDF

Electrostatics-Part 4-4: Standard test methods for specific applications-Electrostatic classification of flexible intermediate bulk containers (FIBC)

$186.00 $371.99 -50%
Product Code: IEC 61340-4-4
Stock In Stock
Edition: 3.0
Published: 01/2018
Number of Pages: 102
File Size: 1 file, 1 Byte

Available Options

Product Description

Electrostatics – Part 4-4: Standard test methods for specific applications – Electrostatic classification of flexible intermediate bulk containers (FIBC)

Introduction: Flexible intermediate bulk containers (FIBC) are widely used for the storage, transportation and handling of powdered, flaked or granular material. Typically, they are constructed from woven polypropylene fabric in the form of cubic bags of about 1 m3 volume, although they can vary in shape and in size from 0,25 m3 to 3 m3. The fabric used may be a single layer, a multi-layer laminate, or a coated fabric. Untreated polypropylene is an electrical insulator, as is often the case with the products placed in FIBC. There is ample opportunity for the generation of electrostatic charge during filling and emptying operations and in unprotected FIBC high levels of charge can quickly build up. In such cases, electrostatic discharges are inevitable and can be a severe problem when FIBC are used in hazardous explosive atmospheres. A hazardous explosive atmosphere can be generated when handling fine powders that create dust clouds or thin layers of powder, both of which can be ignited by electrostatic discharges. A hazardous explosive atmosphere can also be generated when using gases or volatile solvents. In these industrial situations, there is clearly a need to eliminate incendive electrostatic discharges. As with any industrial equipment, a thorough risk assessment should always be conducted before using FIBC in potentially hazardous situations. This part of IEC 61340 describes a system of classification, test methods, performance and design requirements and safe use procedures that ca

Scope: This part of IEC 61340 specifies requirements for flexible intermediate bulk containers (FIBC) between 0,25 m3 and 3 m3 in volume, intended for use in hazardous explosive atmospheres. The explosive atmosphere can be created by the contents in the FIBC or can exist outside the FIBC. The requirements include: classification and labelling of FIBC; classification of inner liners; specification of test methods for each type of FIBC, inner liner, labels and document pockets; design and performance requirements for FIBC, inner liners, labels and document pockets; safe use of FIBC (including those with inner liners) within different zones defined for explosion endangered environments, described for areas where combustible dusts are, or can be, present (IEC 60079-10-2), and for explosive gas atmospheres (IEC 60079-10-1); procedures for type qualification and certification of FIBC, including the safe use of inner liners. NOTE 1 Guidance on test methods that can be used for manufacturing quality control is given in Annex C. The requirements of this document are applicable to all types of FIBC and inner liners, tested as manufactured, prior to use and intended for use in hazardous explosive atmospheres: Zones 1 and 2 (Groups IIA and IIB only) and Zones 21 and 22 (see Annex D for classification of hazardous areas and explosion groups). For some types of FIBC, the requirements of this document apply only to use in hazardous explosive atmospheres with minimum ignition energy of 0,14 mJ or greater and where charging currents do not exceed 3,0 µA. NOTE 2 0,14 mJ represents a realistic minimum ignition energy for a Group IIB gas or vapour atmosphere. Although more sensitive materials exist, 0,14 mJ is the lowest minimum ignition energy of any material that is likely to be present when FIBC are emptied. 3,0 µA is the highest charging current likely to be found in common industrial processes. This combination of minimum ignition energy and charging current represents the most severe conditions that might be expected in practice. FIBC are not normally used in Zone 0 or Zone 20. If FIBC are used in Zone 0 or Zone 20, the requirements of this document are applicable, together with add

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61340-4-4-2018 PDF

IEC 61340-4-4-2018 PDF

$186.00 $371.99