Electrostatics – Part 5-1: Protection of electronic devices from electrostatic phenomena – General requirements (Commented Version)
Introduction: This part of IEC 61340 covers the requirements necessary to design, establish, implement and maintain an electrostatic discharge (ESD) control program for activities that: manufacture, process, assemble, install, package, label, service, test, inspect, transport, or otherwise handle electrical or electronic parts, assemblies, and equipment susceptible to damage by electrostatic discharges greater than or equal to 100 V human body model (HBM), 200 V charged device model (CDM), and 35 V on isolated conductors. Isolated conductors were historically represented by machine model (MM). The 35 V limit is related to the level achievable using ionizers specified in this document. The MM test is no longer required for qualification of devices, only the HBM and CDM tests are. The MM test is retained in this standard for process control of isolated conductors only. 1 Any contact and physical separation of materials or flow of solids, liquids, or particle-laden gases can generate electrostatic charges. Common sources of ESD include charged: personnel, conductors, common polymeric materials, and processing equipment. ESD damage can occur when: a charged person or object comes into contact with an ESD sensitive device (ESDS); an ESDS comes into direct contact with a highly conductive surface while exposed to an electrostatic field; a charged ESDS comes into contact with another conductive surface which is at a different electrical potential. This surface may or may not can be grounded or un
Scope: This part of IEC 61340 applies to organizations that: manufacture, process, assemble, install, package, label, service, test, inspect, transport, or otherwise handle electrical or electronic parts, assemblies and equipment with withstand voltages greater than or equal to 100 V human body model (HBM) and 200 V charge device model (CDM) and 35 V for isolated conductors. Also, protection from isolated conductors is addressed by limiting the voltage on isolated conductors to less than 35 V. ESDS with lower withstand voltages may can require additional control elements or adjusted limits. Processes designed to handle items that have lower ESD withstand voltage(s) can still claim compliance to this document. This document provides the requirements for an ESD control program. IEC TR 61340-5-2 [2] provides guidance on the implementation of this document. This document does not apply to electrically initiated explosive devices, flammable liquids, gases, and powders. The purpose of this document is to provide the administrative and technical requirements for establishing, implementing, and maintaining an ESD control program (hereinafter referred to as the “program”). NOTE Isolated conductors were historically represented by MM.
Contents:
- FOREWORD
- INTRODUCTION
- Scope