Lamp controlgear – Part 2-7: Particular requirements for electric source for safety Services (ESSS) Supplied Electronic Controlgear For Emergency lightning (self-contained)
Introduction: The formatting into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognized. This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which the tests are to be performed; they also include additional requirements, as necessary. All parts which make up IEC 61347-2 are self-contained and, therefore, do not include reference to each other. Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard by the phrase “The requirements of Clause n of IEC 61347-1 apply", this phrase is interpreted as meaning that all requirements of the clause in question of Part 1 apply, except any which are clearly inapplicable to the specific type of lamp controlgear covered by this particular part of IEC 61347-2. INTRODUCTION to Amendment 1 EBLF is the ratio of the light output of a light source in emergency mode to the rated light output under normal conditions. EBLF is controlled by the output characteristics (current, voltage, power) of the controlgear with which the light source is operated. For conventional lamps like fluorescent lamps, the EBLF is defined by the light output ratio of the lamp operated at 100 % and in emergency mode. EBLF = Φemergency / Φ100 % For this measurement no special lamp is required, it is expected that all lamp
Scope: This part of IEC 61347 specifies particular safety requirements for battery electric source for safety services (ESSS) supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by in IEC 60598-2-22. It is intended for controlgear for fluorescent lamps, but it is also applicable to and other lamp types e.g. for example incandescent lamps, high pressure discharge lamps and LEDs. This standard document covers the emergency mode operation of a controlgear. For controlgear with a combination of normal and emergency lighting operation, the normal lighting operation aspects are covered by the appropriate Part 2 of the IEC 61347 series. DC supplied electronic controlgear for emergency lighting may can (or may not) include batteries the electric source for safety services (ESSS). This standard also includes operational requirements for electronic controlgear, which, in the case of d.c. supplied electronic controlgear, are regarded as performance requirements. This is because non-operational emergency lighting equipment presents a safety hazard. It This document does not apply to d.c. supplied electronic controlgear for emergency lighting, which are intended for connection to a centralised centralized emergency power supply system. A centralised centralized emergency power system could be a central battery system. NOTE Annex J of IEC 61347-2-3:2011/AMD1:2016 applies to a.c., a.c./d.c. or d.c. supplied electronic controlgear for connection to centralised centralized emergency power supply systems that are also intended for emergency lighting operations from a.c./d.c. supplies.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 10 Provisions for protective earthing
- 11 Moisture resistance and insulation
- 12 Electric strength
- 13 Thermal endurance test for windings of ballasts controlgear
- 14 Fault conditions Void
- 15 Starting conditions
- 16 Lamp current
- 17 Supply current
- 18 Maximum current in any lead (with cathode preheating)
- 19 Lamp operating current waveforms
- 20 Functional safety (EBLF, EOFX)
- 21 Changeover operation
- 22 Recharging device
- 23 Protection against excessive discharge
- 24 Indicator
- 25 Remote control, rest mode, inhibition mode
- 26 Temperature cycling test and endurance test
- 27 Polarity reversal
- 28 Fault conditions
- 29 Construction
- 30 Creepage distances and clearances
- 31 Screws, current-carrying parts and connections
- 32 Resistance to heat, fire and tracking
- 33 Resistance to corrosion
- 34 Abnormal lamp conditions
- 35 Protection of associated components