Low-voltage switchgear and controlgear assemblies - Part 8: Assemblies for use in photovoltaic installations
Introduction: The photovoltaic technology enables electricity to be produced directly from sunlight, which is a source of renewable energy. Photovoltaic (PV) energy is one of the most promising technologies meeting the pressing need for green renewable energy and is a part of the answer to the challenge of sustainable development. Pushed by sustainable energy policies, extensive country engagement, technology development, and cost reduction, the number of photovoltaic (PV) installations according to IEC 60364-7-712 is increasing rapidly. PV installations are usually split into two main categories: large scale-utility PV installations, where electricity production can be stored or exported to the grid. small PV installations, for example rooftop installation, where the produced energy can be consumed locally or exported to the grid. PV applications have characteristics that require assemblies with specific performance. A typical arrangement of a PV installation is shown in Figure 101. Further examples are provided in Annex FF. Figure 101 – Example of a large scale-utility PV installation
Scope: This part of the IEC 61439 series specifies requirements for the design and verification of low-voltage switchgear and controlgear assemblies for use in photovoltaic installations. PVAs have the following characteristics: assemblies used for the combination of electrical energy in DC systems for which the input and output voltage does not exceed 1 500 V DC; assemblies supplied from an AC network where the voltage does not exceed 1 000 V AC for auxiliary and control purposes; stationary assemblies with an enclosure; assemblies intended for operation by authorised persons (see IEC 61439-1:2020, 3.7.17), but can be located in an area accessible to ordinary persons (see IEC 61439-1:2020, 3.7.16); suitable for indoor or outdoor installation. NOTE 1 PV installations having PV modules with micro-inverters that are connected directly to inter-connection assemblies according to IEC 61439-2 or IEC 61439-3 are not covered by this document. NOTE 2 Requirements for PVA including other types of DC distribution circuits, for example battery circuits, connected in the same assembly are under consideration. This document identifies definitions, specifies the service conditions, details the construction requirements, defines the technical characteristics, and provides verifications for PVAs. PVAs can also include control or signalling devices, or both, associated with the distribution of electrical energy. This document applies to all PVAs whether they are designed and manufactured on a one-off basis or fully standardized and manufactured in quantity. Either the manufacture or assembly, or both, can be carried out by an entity other than the original manufacturer (see IEC 61439-1:2020, 3.10.1). This document does not apply to: individual devices, for example, circuit-breakers, fuse switches and self-contained components such as, motor starters, switch mode power supplies (SMPS), uninterruptable power supplies (UPS), basic drive modules (BDM), complete drive modules (CDM), adjustable speed power drives systems (PDS), stand-alone energy storage systems (battery and capacitor systems), other electronic equipment which comply with their relevant product standards, such as junction bo
Contents:
- FOREWORD
- INTRODUCTION
- Scope