Nuclear instrumentation-Measurement of activity or emission rate of gammaray emitting radionuclides-Calibration and use of germanium-based spectrometers

$255.36 $510.71 -50%
Product Code: IEC 61452
Stock In Stock
Edition: 2.0
Published: 06/2021
Number of Pages: 102
File Size: 1 file, 4 Bytes

Available Options

Product Description

Nuclear instrumentation – Measurement of activity or emission rate of gammaray emitting radionuclides – Calibration and use of germanium-based spectrometers

Introduction: A typical gamma-ray spectrometer consists of a high purity germanium (HPGe) detector with its liquid nitrogen or mechanically refrigerated cryostat and preamplifier, associated to either analog or digital electronic modules including the detector biasing and signal processing (amplification, multichannel conversion and storage) and data-readout devices. The spectrometers include or are associated with computers and their acquisition software. A radiation shield often surrounds the detector to reduce the counting rate from room background radiation for shield construction guidelines). Primary interactions of the photons (X- and gamma-rays) in the HPGe crystal (by photoelectric absorption, Compton scattering or pair production) impart energy to electrons whose energy is finally released by creation of electron-hole pairs. These electrons and holes are collected to produce a pulse whose amplitude is proportional to the energy deposited in the active volume of the HPGe crystal. These pulses are amplified, shaped and sorted according to pulse height to produce a histogram showing, as a function of energy, the number of photons absorbed by the detector. After the accumulation of a sufficient number of pulses the histogram will display a spectrum with one or more peaks with an approximately normal (Gaussian) distribution corresponding to photons that transferred their entire energy to the detector. These are superimposed on continuum constituted by the events related to the partial

Scope: This document establishes methods for the calibration and use of high purity germanium spectrometers for the measurement of photon energies and emission rates over the energy range from 45 keV to approximately 3 000 keV and the calculation of radionuclide activities from these measurements. Minimum requirements for automated peak finding are stated. This document establishes methods for measuring the full-energy peak efficiency with calibrated sources. Performance tests are described that ascertain if the spectrometer is functioning within acceptable limits. These tests evaluate the limitations of the algorithms used for locating and fitting single and multiplet peaks. Methods for the measurement of and the correction for pulse pile-up are suggested. A test to ascertain the approximate magnitude of true coincidence summing is described. Techniques are recommended for the inspection of spectral analysis results for large errors resulting from true coincidence summing of cascade gamma-rays in the detector. Suggestions are provided for the establishment of data libraries for radionuclide identification, decay corrections, the conversion of gamma-ray emission rates to decay rates and Monte Carlo simulations. The measurement of X-ray emission rates is not included because different functional fits are required for X-ray peaks, which have intrinsically different peak shapes than gamma-ray peaks. Further, X-ray peaks are complex multiplets (e.g., the K X-rays of Tl include 10 individual components that form four partially resolved peaks). This document does not address the measurement of emission rates of annihilation radiation peaks or single- and double-escape peaks resulting from partial energy deposition in the detector from pair production. Escape peaks may require different fitting functions than comparable full-energy peaks. Further, annihilation radiation and single-escape peaks have a different and larger width than a gamma-ray peak of similar energy. Discussion of acceptable methods for measuring the lower limits of detection as they relate to specific radionuclides is beyond the scope of this document. The object of this document is to provide a basis for th

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61452-2021 PDF

IEC 61452-2021 PDF

$255.36 $510.71