Live working – Phase comparators – Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c.
Introduction: This International Standard has been prepared in accordance with the requirements of IEC 61477. Taking into consideration the two different functioning principles of portable phase comparators of capacitive type available on the market, the maximum a.c. nominal voltage to be associated with each of them has been considered for delimiting the scope of this standard. The following table presents the rationale for the resulting maximum nominal voltage to be associated with each functioning principle of phase comparator of capacitive type. Functioning principle Maximum nominal voltage kV rms Rationale Single-pole phase comparators operating with a memory system – With this principle of functioning, the clear indication of the phase comparator is limited by the memory holding time. With higher nominal voltages, the distance between phases of the installation increases and the time necessary to move the pole of the phase comparator between the two parts to be compared becomes the limitation. Two-pole phase comparators operating with a wireless connection – With this principle of functioning, there is no theoretical limit for the maximum nominal voltage. – The definition of 245 kV corresponds to the present limit of validation of the electric test set-up. The product covered by this standard may have an impact on the environment during some or all stages of its life cycle. These impacts can range from slight to significant, be short-term or long-term, and occur at the global, region
Scope: This part of IEC 61481 is applicable to portable phase comparators of capacitive type to be used on electrical systems for voltages exceeding 1 kV a.c. and frequencies of 50 Hz and/or 60 Hz. This standard is applicable to: single-pole phase comparators of capacitive type operating with a memory system up to 36 kV a.c., two-pole phase comparators of capacitive type operating with a wireless connection up to 245 kV a.c. This standard is applicable to phase comparators of capacitive type used in contact with the bare conductive parts to be compared: as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this standard. NOTE Some parts such as the contact electrode or the insulating element of a phase comparator as a complete device may be dismantled. Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see Annex A). A device that is designed to provide other functions than phase comparison is a different device and is not covered by this standard. For example a device designed to be also used as a voltage detector is not covered by this standard (see Annex A). Products designed and manufactured according to this standard contribute to the safety of users provided they are used by persons trained for the work, in accordance with the hot stick working method and the instructions for use. Except when otherwise specified, all the voltages defined in this standard refer to phase-to- phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages should be used to determine the operating voltage.
Contents:
- FOREWORD
- INTRODUCTION
- Scope