Safety of transformers, reactors, power supply units and combinations thereof – Part 1: General requirements and tests
Introduction: This document covers safety requirements for transformers. Where the term transformer is used, it covers transformers, reactors and power supplies supply units where applicable. During the development of this document, to the extent possible, the requirements of IEC 60364 (all parts) were taken into consideration, so that a transformer may can be installed in accordance with the wiring rules contained in that document. However, national wiring rules may can differ. This document recognizes the internationally accepted levels of protection against the possible electrical, mechanical, and fire hazards caused by transformers operating under normal conditions in accordance with the manufacturer's instructions. It also covers abnormal conditions which may can occur in practice. A transformer complying with this document will not necessarily be judged to comply with the safety principles of this document if, when examined and tested, it is found to have other features that impair the level of safety covered by these requirements. A transformer employing materials or having forms of construction differing from those detailed in this document may be examined and tested according to the intent of the requirements and, if found to be substantially equivalent, may be judged to comply with the safety principles of this document. The document dealing with non-safety aspects of electromagnetic compatibility (EMC) of transformers is IEC 62041: Power transformers, power supply units, reactor
Scope: This part of IEC 61558 deals with safety aspects of power transformers, power supplies, reactors, power supply units and similar products combinations thereof such as electrical, thermal and mechanical safety. This document covers the following independent or associated stationary or portable types of dry-type transformers, power supplies supply units, including switch mode power supplies supply units, reactors and combinations thereof in the field of safety. The windings of which may can be encapsulated or non-encapsulated. They are not forming a part of the distribution network. NOTE 1 The distinction between transformers, power supplies supply units and switch mode power supplies supply units is as follows: for transformers, there is no change in frequency. However, transformers (e.g. constant voltage transformers) may can have an internal resonance frequency not exceeding 30 kHz; for power supplies supply units, the internal operational frequency and waveform are different from the supply frequency and waveform, and the internal operational frequency does not exceed 500 Hz (see definition 3.1.19); for switch mode power supplies supply units, the internal operational frequency and waveform are different from the supply frequency and waveform and the internal operational frequency exceeds 500 Hz and does not exceed 100 MHz. The relevant parts of IEC 61558-2 may can be found in the introduction of this document. a) Stationary or portable, single-phase or poly-phase, air-cooled (natural or forced), isolating and safety isolating transformers, independent or associated, not forming a part of distribution networks and with the following characteristics: rated supply voltage not exceeding 1 000 V AC; rated supply frequency not exceeding 500 Hz; and complying with the following values, unless otherwise specified in the relevant part of IEC 61558-2: for isolating transformers: rated output for single phase transformers, not exceeding 25 kVA, and for poly- phase transformers not exceeding 40 kVA; no-load output voltage and the rated output voltage exceeding 50 V AC, and not exceeding 500 V a.c, or 1 000 V AC to be in accordance with the national wiring rules or for a
Contents:
- FOREWORD
- INTRODUCTION
- Scope