Safety of transformers, reactors, power supply units and combinations thereof – Part 2-10: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, which is about electrical installations and protection against electric shock, but in certain cases including the limitation of voltage and horizontal safety function for SELV, in accordance with IEC 60364-4-41. The group safety function (GSF) is used because of responsibility for safety extra-low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2005, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is used for each part of IEC 61558-2 because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement: This part of IEC 61558 deals with the safety of separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V AC or 1 500 V DC. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry-type transformers. The windings can be encapsulated or non-encapsulated. For power supply units (linear) this document is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe takes precedence. The rated supply voltage does not exceed 1 000 V AC, and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated output does not exceed: 25 kVA for single-phase transformers; 40 kVA for polyphase transformers. This document is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. Where applicable the no-load output voltage or the rated output voltage: does not exceed 1 000 V AC or 1 500 V DC for separating transformers with high insulation level; does exceed 1 000 V AC or 1 500 V DC and does not exceed 15 000 V AC or 15 000 V DC for separating transformers with output voltage exceeding 1 000 V. This document does not apply to: transformers covered by IEC 60076-11; neon transformers covered by IEC 61050; and power supplies and converters for use with or in products according to IEC 61347-2-10. IEC 61558-2-10:2024 IEC 2024 – 7 – This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. NOTE 2 Transformers covered by this document are used only in applications where double o
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 1 000 V