IEC 61558-2-10 EXV-2024 PDF

IEC 61558-2-10 EXV-2024 PDF

Safety of transformers, reactors, power supply units and combinations thereof-Part 2-10: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V (Extended Version)

$509.45 $1,018.89 -50%
Product Code: IEC 61558-2-10 EXV
Stock In Stock
Edition: 2.0
Published: 06/2024
Number of Pages: 218
File Size: 1 file

Available Options

Product Description

Safety of transformers, reactors, power supply units and combinations thereof – Part 2-10: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V (Extended Version)

Scope: This part of IEC 61558 deals with the safety of separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V AC or 1 500 V DC. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry-type transformers. The windings can be encapsulated or non-encapsulated. For power supply units (linear) this document is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe takes precedence. The rated supply voltage does not exceed 1 000 V AC, and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated output does not exceed: 25 kVA for single-phase transformers; 40 kVA for polyphase transformers. This document is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. Where applicable the no-load output voltage or the rated output voltage: does not exceed 1 000 V AC or 1 500 V DC for separating transformers with high insulation level; does exceed 1 000 V AC or 1 500 V DC and does not exceed 15 000 V AC or 15 000 V DC for separating transformers with output voltage exceeding 1 000 V. This document does not apply to: transformers covered by IEC 60076-11; neon transformers covered by IEC 61050; and power supplies and converters for use with or in products according to IEC 61347-2-10. – 16 – IEC 61558-2-10:2024 EXV  IEC 2024 This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. NOTE 2 Transformers covered by this document are used only in applications where double or reinfo

Contents:

  • FOREWORD
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61558-2-10 EXV-2024 PDF

IEC 61558-2-10 EXV-2024 PDF

$509.45 $1,018.89