Safety of transformers, reactors, power supply units and combinations thereof – Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, but in certain cases including the limitation of voltage and horizontal safety function for SELV, in accordance with IEC 60364-4-41. The group safety function (GSF) is used because of responsibility for example for safety extra- low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2005, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is used for each part of IEC 61558-2 because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement: This part of IEC 61558 deals with the safety of auto-transformers for general applications and power supply units incorporating auto-transformers for general applications. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers auto-transformers for general applications and power supply units incorporating auto-transformers for general applications. NOTE 2 For power supply units (linear) this document is applicable. For switch mode power supply units IEC 61558-2-16 is applicable together with this part. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry-type transformers. The windings may can be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 100 1 000 V AC, and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The core power does not exceed: 2 kVA for single-phase transformers; 10 kVA for polyphase transformers. The rated output does not exceed: 40 kVA for single-phase transformers; 200 kVA for polyphase transformers. This document is applicable to transformers without limitations of the core power and the rated output both being subject to an agreement between the purchaser and the manufacturer. Where applicable, the no-load output voltage or the rated output voltage does not exceed 1 000 V AC or 1 415 V ripple-free DC. For independent transformers, the no-load output voltage and the rated output voltage exceeds is not less than 50 V AC or 120 V ripple-free DC. This document is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. – 8 – IEC 61558-2-13:2022 RLV IEC 2022 NOTE 2 Transformers covered by this document are used only in applications where no insulation between circuits is required by the installation rules or by the end product standard. NOTE 3 Attention is drawn to the following, if necessary: for transformers intended to b
Contents:
- FOREWORD
- INTRODUCTION
- Scope