Safety of transformers, reactors, power supply units and combinations thereof – Part 2-14: Particular requirements and tests for variable transformers and power supply units incorporating variable transformers for general applications
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, but in certain cases including limitation of voltage and horizontal safety function for SELV in accordance with IEC 60364-4-41. The group safety function (GSF) is necessary because of responsibility e.g. for safety extra-low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2005, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is needed for each part of IEC 61558-2 because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement This part of IEC 61558 deals with the safety of variable transformers for general applications and power supply units incorporating variable transformers for general applications. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal, mechanical and chemical aspects. Unless otherwise specified, from here onward, the term transformer covers variable transformers for general applications and power supply units incorporating variable transformers for general applications. For power supply units (linear) this document is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe take precedence. This document does not apply to transformers covered by IEC 60076-11. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated variable dry-type transformers: variable auto-transformers; variable separating transformers; variable isolating transformers; variable safety isolating transformers. The windings can be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V AC and the rated supply frequency and the internal operational frequencies do not exceed 500 Hz. The rated output does not exceed: 40 kVA for single-phase variable auto-transformers; 200 kVA for polyphase variable auto-transformers; 1 kVA for single-phase variable separating transformers; 5 kVA for polyphase variable separating transformers; 25 kVA for single-phase variable isolating transformers; 40 kVA for polyphase variable isolating transformers; 10 kVA for single-phase variable safety isolating transformers; 16 kVA for polyphase variable safety isolating transformers. This document is applicable to variable transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 2 Transformers intended to supply distribution networks are not included in the scope. IEC 61558-2-14:2022 IEC 2022 – 7 – For variable auto-transformers: the no-load output voltage or the r
Contents:
- FOREWORD
- INTRODUCTION
- Scope