Safety of transformers, reactors, power supply units and combinations thereof – Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units for general applications
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, but in certain cases including the limitation of voltage and horizontal safety function for SELV, in accordance with IEC 60364-4-41. The group safety function (GSF) is necessary because of responsibility for safety extra-low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2017, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is needed for each part of IEC 61558-2 because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example, an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement This part of IEC 61558 deals with the safety of switch mode power supply units and transformers for switch mode power supply units. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term SMPS covers switch mode power supply units for general applications. SMPS covered by this document are air cooled (natural or forced) independent, associated, stationary, portable, single-phase or polyphase with the rated supply voltage not exceeding 1 000 V AC, the rated supply frequency not exceeding 500 Hz, the rated internal operating frequency exceeding 500 Hz, but not exceeding 100 MHz, and the rated output not exceeding 1 kVA or 1 kW, incorporating dry-type transformers with encapsulated or non-encapsulated windings. NOTE 2 As the maximum rated supply voltage of the internal transformer is 1 000 V AC, the maximum rated supply voltage of the switch mode power supply unit can be lower due to the type of rectification. NOTE 3 For higher frequencies, additional requirements can be necessary. However, this document can be used for guidance. This document is applicable to SMPS, converters and inverters without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 4 In the context of this document, converters and inverters are considered to be SMPS. This document applies to: a) SMPS incorporating safety isolating transformers providing SELV, PELV, AC or DC output voltage(s) or a combination thereof in accordance with IEC 61140 and IEC 60364- 4-41 for use with household and other consumer products, b) SMPS with a maximum output voltage not exceeding 1 000 V AC or 1 415 V ripple-free DC for use with household and other consumer products, except for products covered in a), c) This document can be used for transformers for use in SMPS (see Annex BB). This document does not apply to: motor-generator sets; uninterruptible power supplies (UPS) in accordance with the IEC 62040 series; SMPS covered by IEC 61204-7 (i.e. low-voltage power supply devices DC output, performance characteristics) and DC power and distribution equipment and SMPS for use in application
Contents:
- FOREWORD
- INTRODUCTION
- Scope