Safety of transformers, reactors, power supply units and combinations thereof – Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, but in certain cases including the limitation of voltage and horizontal safety function for SELV, in accordance with IEC 60364-4-41. The group safety function (GSF) is used because of responsibility for example for safety extra- low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2005, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is used for each part of the IEC 61558-2 series because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement: This part of IEC 61558 deals with the safety aspects of control transformers and power supplies supply units incorporating control transformers. Transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical safety aspects. This Part 2-2 is applicable to control transformers and power supplies incorporating both control transformers and electronic circuits. This Part 2-2 is not applicable to external circuits and their components intended to be connected to the input terminals, output terminals or socket-outlets of the transformer and power supplies. Unless otherwise specified, from here onward, the term transformer covers control transformers and power supply units incorporating control transformers. For power supply units (linear) this document is applicable. For switch mode power supply units IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe take precedence. This document does not apply to transformers covered by IEC 60076-11. This Part 2-2 applies to stationary or portable, single-phase or poly-phase, air-cooled (natural or forced), independent or associated control transformers and power supplies incorporating a control transformer, having a rated supply voltage not exceeding 1 000 V a.c. and rated supply and internal operating frequency not exceeding 500 Hz. This document is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry-type transformers. The windings can be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V AC and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated thermal output does not exceed: 25 kVA for single-phase control transformers and power supplies incorporating control transformers, 40 kVA for polyphase control transformers and power supplies incorporating control transformers. This document is applicable to control transformers and power supplies incorporating control transformers without limitation of the rated thermal output, subject
Contents:
- FOREWORD
- INTRODUCTION
- Scope