Safety of transformers, reactors, power supply units and combinations thereof – Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, which is about Electrical installations and protection against electric shock, but in certain cases including the limitation of voltage and horizontal safety function for SELV, in accordance with IEC 60364-4-41. The group safety function (GSF) is used because of responsibility for example for safety extra- low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2017, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is used for each part of IEC 61558-2 because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement: This part of IEC 61558 deals with the safety of shaver transformers, power supply units incorporating a shaver transformer, and shaver supply units. Shaver transformers incorporating electronic circuits are also covered by this document. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers shaver transformers and power supply units incorporating shaver transformers and shaver supply units. For power supply units (linear) this document is applicable. For switch mode power supply units IEC 61558-2-16 is applicable together with this document. Where two requirements are in conflict, the most severe take precedence. This document is applicable to stationary, single-phase, air-cooled (natural or forced) independent or associated dry-type transformers. The windings can be encapsulated or non- encapsulated. The rated supply voltage does not exceed 250 V AC and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated output is not less than 20 VA and does not exceed 50 VA. The no-load output voltage does not exceed 275 V AC and the rated output voltage does not exceed 250 V AC. This document is not applicable to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformers. NOTE 2 Transformers covered by this document are only used in applications where double or reinforced insulation between circuits is specified by the installation rules for bathrooms and similar locations, or by the appliance specifications. NOTE 3 Transformers covered by this document can be flush or surface mounted or incorporated in luminaires, mirrors, and other equipment containing one or more socket-outlet(s). Attention is drawn to the following, if applicable: for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.); measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing; th
Contents:
- FOREWORD
- INTRODUCTION
- Scope