Radiation protection instrumentation in nuclear facilities – Centralized systems for continuous monitoring of radiation and/or levels of radioactivity – Part 1: General requirements
Introduction: a) Technical background, main issues and organisation of this standard This IEC standard specifically applies to centralized systems intended for continuous monitoring of radiation and/or levels of radioactivity in nuclear facilities, primarily in support of radiological protection in the working areas. These centralized systems play an auxiliary or indirect role in the achievement or maintenance of a nuclear facility’s safety. These are classified as category C in IEC 61226 since they include functions that have some safety significance. This standard is intended for use by purchasers in developing specifications for their plant specific centralized systems radiation monitoring systems and by manufacturers to identify needed product characteristics when developing systems. This standard is one associated with a series of standards which cover process and safety monitoring, and radiation protection and effluents monitoring in nuclear facilities. The full series is detailed in paragraph b) below. b) Situation of the current standard in the structure of the IEC SC 45A/SC 45B standard series IEC 60951 series of standards are at the third level in the hierarchy of SC 45A standards. They provide guidance on the design and testing of radiation monitoring equipment used for accident and post accident conditions. IEC 60951-1 – General requirements IEC 60951-2 – Equipment for continuous off-line monitoring of radioactivity in gaseous effluents and ventilation air IEC 60951-3 – Equipme
Scope: Sampling circuits and methods Accident and post accident conditions Normal and incident conditions SC 45B – radiation protection and effluents monitoring Gas, particulate and iodine with sampling (OFF LINE) ISO 2889 IEC 60951-1 and -2 IEC 60761 series Liquid with sampling N/A N/A IEC 60861 61559-1 © IEC:2009 – 7 – (OFF LINE) Process stream (gaseous effluents, steam or liquid) without sampling (ON or IN-LINE) N/A IEC 60951-1 and -4 IEC 60768 N/A Area monitoring N/A IEC 60951-1 and -3 IEC 60532 Central system N/A IEC 61504 IEC 61559 c) Recommendations and limitations regarding the application of this standard It is important to note that this standard establishes no additional functional safety requirements for safety systems. d) Description of the structure of the IEC SC 45A/SC 45B standard series and relationships with other IEC documents and other bodies’ documents (IAEA, ISO) The basic safety publication is IEC 61508-7, Functional safety of electrical/electronic/ programmable electronic safety-related systems. It defines the requirements for an overall safety life-cycle framework and a system life-cycle framework. IEC 61508 should be complied with when developing instruments with safety functions for centralized systems of radiation monitoring outside the nuclear power plant sector whilst complying with the requirements defined in this standard. The top-level document of the IEC SC 45A standard series is IEC 61513. It provides general requirements for I&C systems and equipment that are used to perform functions important to safety in nuclear power plants. IEC 61513 structures the IEC SC 45A standard series. IEC 61513 refers directly to other IEC SC 45A standards for general topics related to categorization of functions and classification of systems, qualification, separation of systems, defence against common cause failure, software aspects of computer-based systems, hardware aspects of computer-based systems, and control room design. The standards referenced directly at this second level should be considered together with IEC 61513 as a consistent document set. At a third level, IEC SC 45A/SC 45B standards not directly referenced by IEC 61513 are standards re
Contents:
- FOREWORD
- INTRODUCTION
- Scope