IEC 61674-2024 PDF

IEC 61674-2024 PDF

Medical electrical equipment-Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging

$163.93 $327.86 -50%
Product Code: IEC 61674
Stock In Stock
Edition: 3.0
Published: 07/2024
Number of Pages: 80
File Size: 1 file, 1 Byte

Available Options

Product Description

Medical electrical equipment – Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging

Introduction: Diagnostic radiology is the largest contributor to man-made IONIZING RADIATION to which the public is exposed. The reduction in the exposure received by PATIENTS undergoing medical radiological examinations or procedures has therefore become a central issue in recent years. The PATIENT dose will be minimized when the X-ray producing equipment is correctly adjusted for image quality and radiation output. These adjustments require that the routine measurement of AIR KERMA, AIR KERMA LENGTH PRODUCT and/or AIR KERMA RATE be made accurately. The equipment covered by this document plays an essential part in achieving the required accuracy. It is important that the DOSIMETERS used for adjustment and control measurements are of satisfactory quality and therefore fulfil the special requirements laid down in this document.

Scope: This document specifies the performance and some related constructional requirements of DIAGNOSTIC DOSIMETERS intended for the measurement of AIR KERMA, AIR KERMA LENGTH PRODUCT or AIR KERMA RATE, in photon radiation fields used in medical X-ray imaging, such as RADIOGRAPHY, RADIOSCOPY and COMPUTED TOMOGRAPHY (CT), for X-RADIATION with generating potentials in the range of 20 kV to 150 kV. This document is applicable to the performance of DOSIMETERS with VENTED IONIZATION CHAMBERS and/or SEMICONDUCTOR DETECTORS as used in X-ray diagnostic imaging. 1.2 Object The object of this document is a) to establish requirements for a satisfactory level of performance for DIAGNOSTIC DOSIMETERS, and b) to standardize the methods for the determination of compliance with this level of performance. This document is not concerned with the safety aspects of DOSIMETERS. The DIAGNOSTIC DOSIMETERS covered by this document are not intended for use in the PATIENT ENVIRONMENT and, therefore, the requirements for electrical safety applying to them are contained in IEC 61010-1.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope