IEC 61869-1-2023 PDF

IEC 61869-1-2023 PDF

Instrument transformers-Part 1: General requirements

$271.12 $542.23 -50%
Product Code: IEC 61869-1
Stock In Stock
Edition: 2.0
Published: 06/2023
Number of Pages: 290
File Size: 1 file, 7 Bytes

Available Options

Product Description

Instrument transformers – Part 1: General requirements

Introduction: This document is the first revision of IEC 61869-1, defining common requirements for instrument transformers, applicable to all types or technologies. Furthermore, the document is the result of a merger of IEC 61869-1:2007 (General requirements) and IEC 61869-6:2016 (Additional general requirements for low-power instrument transformers) with the aim of having one single document and simplify the comprehension for the reader of LPIT product-specific standards. The main modifications of this revision are listed below: new scope: equipment for HV applications with a nominal voltage > 1 kV AC or 1,5 kV DC; transfer of the definitions to the TC 38 Glossary IEC 61869-99; ratings: addition of HV insulation levels above 800 kV; new DC insulation resistance requirements for secondary terminals; additional accuracy class extensions for harmonics; design and construction: additional mechanical requirements for EHV applications; clarification of the altitude correction for external insulation and dielectric tests; multiple chopped impulse test: definition of maximum gas-in-oil level before test; internal arc fault protection: simplification of the acceptance criteria; new requirements for storage climatic conditions withstand capability for LPIT; type tests: temperature rise test: more accurate definition of the test duration; lightning impulse test: new test procedure (15 impulses) for gas-insulated and resin- insulated instrument transformers, for Um ≥ 300 kV; switching impulse test: t

Scope: This part of IEC 61869 is applicable to newly manufactured instrument transformers intended for applications where the nominal voltage is higher than 1 kV AC or 1,5 kV DC, with an analogue or a digital secondary signal for measuring, protection and control purposes, with rated frequencies from 15 Hz to 400 Hz, or for DC applications. NOTE 1 A bushing type current transformer, although having no primary insulation level for itself is often placed on a system with a nominal voltage > 1 kV AC or > 1,5 kV DC and therefore falls within the scope of this document. Example: CT placed around an HV bushing or a cable. The general requirements for instrument transformers for applications in LV systems (nominal voltage ≤ 1 kV AC or ≤ 1,5 kV DC) are covered by IEC 61869-201. This part of IEC 61869 is a product family standard and covers general requirements only. For each type of instrument transformer, the product standard is composed of this document and the relevant specific product standard. This part of IEC 61869 contains the requirements for the limits of the errors both for analogue and digital secondary signals. The other characteristics of a digital interface for instrument transformer are standardised in IEC 61869-9 as an application of the IEC 61850 horizontal standard series, covering communication networks and systems for power utility automation. This part of IEC 61869 considers bandwidth requirements. The accuracy requirements on harmonics and requirements for the anti-aliasing filter are specified in 5.7. In the case of an LPIT, the general block diagram of single-phase devices is given in Figure 1. According to the technology, it is not always necessary that all parts described in Figure 1 be included in the instrument transformer. Figure 1 – General block diagram of single-phase LPITs NOTE 2 A secondary power supply can be combined with a primary power supply or with a power supply of other instrument transformers.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61869-1-2023 PDF

IEC 61869-1-2023 PDF

$271.12 $542.23