Medical electrical equipment-Radiation dose documentation-Part 1: Radiation dose structured reports for radiography and radioscopy

$163.93 $327.86 -50%
Product Code: IEC 61910-1
Stock In Stock
Edition: 1.0
Published: 09/2014
Number of Pages: 68
File Size: 1 file, 619 Bytes

Available Options

Product Description

Medical electrical equipment – Radiation dose documentation – Part 1: Radiation dose structured reports for radiography and radioscopy

Introduction: Documentation of the amount of IONIZING RADIATION used during a RADIOLOGICAL procedure is valuable for several reasons. For all procedures dose documentation provides information needed to estimate radiogenic risk to the population. It also plays a role in general institutional quality assurance by providing data for performance validation against established RADIATION dose reference levels. Detailed documentation makes a significant contribution to clinical management of PATIENTS following those interventional procedures that might induce tissue reactions. The transition from imaging on film to digital imaging opened the possibility of automatically recording dose and other data with the images. The Digital Imaging and Communications in Medicine (DICOM) protocol traditionally provides some relevant facilities for doing this in image headers. This has had several limitations. The most obvious of these is the lack of a means for storing dose data without storing images. Thus, radioscopic data was seldom stored; and no dose data was stored if the images were not stored. Improving dose documentation was addressed jointly by the International Electrotechnical Commission (IEC) and the DICOM Standards Committee. Supplement 94 to the DICOM standard was approved in 2005 and incorporated since the 2006 edition of the standard. The DICOM standard now provides the technical format needed to store the entire description of the dose used to perform a single imaging procedure. This first e

Scope: This International Standard applies to RADIATION DOSE STRUCTURED REPORTS (RDSR) produced by X-RAY EQUIPMENT that falls within the scope of IEC 60601-2-43:2010 or IEC 60601-2- 54:2009. NOTE 1 The intent is to develop and publish similar documents for other X-ray imaging modalities capable of producing RDSRs. NOTE 2 This document does not impose specific requirements on the accuracy of the reported or displayed data. Existing standards or regulations can have applicable requirements for accuracy and precision. This standard provides specific units and quantities and prescribes data storage formats. NOTE 3 The data formats are specified such that the numerical uncertainty attributable to the format is likely to be small compared to other data uncertainties. NOTE 4 This document does not present any requirements on the form of display of dose information to OPERATORS or other individuals. The objective of this International Standard is to specify the minimum dataset to be used for reporting dosimetric and related information associated with the production of projection RADIOLOGICAL IMAGES. NOTE 5 The data fields and report structure are intended to facilitate the collection of dosimetric data useful for: management of procedures delivering significant dose, facility quality programs, establishment of reference levels, education. NOTE 6 A public structure facilitates data analysis by any appropriate individual or organization.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61910-1-2014 PDF

IEC 61910-1-2014 PDF

$163.93 $327.86