Electricity metering equipment (a.c.) General requirements, tests and test conditions Part 21: Tariff and load control equipment
Introduction: This standard distinguishes between protective class I and protective class II tariff and load control equipment. The test levels are regarded as minimum values to guarantee the proper functioning of the equipment under normal working conditions. For special application, other test levels might be necessary and should be agreed on between the user and the manufacturer. For information, the relevant parts of IEC 62052, IEC 62054 and IEC 62059 are listed: IEC 62052-21, Electricity metering (a.c.) – General requirements, tests and test conditions – Part 21: Tariff and load control equipment (Replaces the general requirements of IEC 61037 and IEC 61038.) IEC 62052-31:2015, Electricity metering equipment (AC) – General requirements, tests and test conditions – Part 31: Product safety requirements and tests IEC 62054-11, Electricity metering (a.c.) – Tariff and load control – Part 11: Particular requirements for electronic ripple control receivers (Replaces the particular requirements of IEC 61037.) IEC 62054-21, Electricity metering (a.c.) – Tariff and load control – Part 21: Particular requirements for time switches1 (Replaces the particular requirements of IEC 61038.) IEC 62059-11, Electricity metering equipment (a.c.) – Dependability – Part 11: General concepts IEC 62059-21, Electricity metering equipment (a.c.) – Dependability – Part 21: Collection of meter dependability data from the field IEC 62059-41, Electricity metering equipment (a.c.) – Dependability – Part 41: Reliabil
Scope: This part of IEC 62052 specifies general requirements for the type test of newly manufactured indoor tariff and load control equipment, like electronic ripple control receivers and time switches that are used to control electrical loads, multi-tariff registers and maximum demand indicator devices. This standard gives no requirements for constructional details internal to the tariff and load control equipment. In the case where tariff and load control functionality is integrated into multifunction electricity metering equipment, the relevant parts of this standard apply. This standard does not cover the acceptance tests and the conformity tests. Nevertheless, an example of what could be an acceptance test is given in Annex F. The safety aspect is covered by IEC 62052-31:2015. The dependability aspect is covered by the documents of the IEC 62059 series.
Contents:
- FOREWORD
- INTRODUCTION
- Scope