Electricity metering equipment – Particular requirements – Part 24: Static meters for fundamental component reactive energy (classes 0,5S, 1S, 1, 2 and 3)
Introduction: This part of IEC 62053 is to be used with relevant parts of the IEC 62052, IEC 62058 and IEC 62059 series, Electricity metering equipment, and with the IEC 62055 series, Electricity metering – Payment systems: IEC 62052‑11:2020, Electricity metering equipment – General requirements, tests and test conditions – Part 11: Metering equipment IEC 62052‑31:2015, Electricity metering equipment (AC) – General requirements, tests and test conditions – Part 31: Product safety requirements and tests IEC 62053‑11:2003, Electricity metering equipment (AC) – Particular requirements – Part 11: Electromechanical meters for active energy (classes 0,5, 1 and 2) IEC 62053-21:2020 Electricity metering equipment – Particular requirements – Part 21: Static meters for AC active energy (classes 0,5, 1 and 2) IEC 62053‑22:2020, Electricity metering equipment – Particular requirements – Part 22: Static meters for AC active energy (classes 0,1 S, 0,2S and 0,5 S) IEC 62053‑23:2020, Electricity metering equipment – Particular requirements – Part 23: Static meters for reactive energy (classes 2 and 3) IEC 62055‑31:2005 Electricity metering – Payment systems – Part 31: Particular requirements – Static payment meters for active energy (classes 1 and 2) IEC 62057‑1: – Test equipment, techniques and procedures for electrical energy meters – Part 1: Stationary Meter Test Units (MTU) IEC 62058‑11:2008, Electricity metering equipment (AC) – Acceptance inspection - –Part 11: General acceptance inspection methods
Scope: This part of IEC 62053 applies only to static var-hour meters of accuracy classes 0,5 S, 1 S, 1, 2 and 3 for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only. This document uses a conventional definition of reactive energy where the reactive power and energy is calculated from the fundamental frequency components of the currents and voltages only (see Clause 3). NOTE 1 This differs from IEC 62053-23, where reactive power and energy is only defined for sinusoidal signals. In this document reactive power and energy is defined for all periodic signals. Reactive power and energy is defined in this way to achieve proper reproducibility of measurements with meters of different designs. With this definition, reactive power and energy reflects the generally unnecessary current possible to compensate with capacitors rather than the total unnecessary current. NOTE 2 For other general requirements, such as safety, dependability, etc., see the relevant IEC 62052 or IEC 62059 standards. This document applies to electricity metering equipment designed to: measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC; NOTE 3 For AC electricity meters, the voltage mentioned above is the line-to-neutral voltage derived from nominal voltages. See IEC 62052-31:2015, Table 7; have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; operate with integrated or detached indicating displays, or without an indicating display; be installed in a specified matching socket or rack; optionally, provide additional functions other than those for measurement of electrical energy. Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be considered as compliant with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters. NOTE 4 Modern electricity meters typically contain additional functions such as measurement of voltage magnitude, current magnitude, power, frequenc
Contents:
- FOREWORD
- INTRODUCTION
- Scope