Medical device software - Requirements for the safety of radiotherapy treatment planning systems
Introduction: A radiotherapy treatment planning system is used to simulate the application of radiation to a patient. An important function of radiotherapy treatment planning system is to provide estimates of absorbed dose distributions in tissue using a particular algorithm or series of algorithms. These estimations, referred in this document as absorbed dose distributions, are used by a qualified person in planning a radiotherapy treatment course. This document recognizes that modern radiotherapy treatment planning system use off-the- shelf hardware with manufacturer written software and therefore concerns itself with the safety of radiotherapy treatment planning software that is type tested against the hardware configurations specified by the manufacturer. It is this combination of software and hardware that is referred to as the radiotherapy treatment planning system in this document. The output of a radiotherapy treatment planning system is used by appropriately qualified persons for clinical decisions and for treatment delivery. Inaccuracies in the input data, the limitations of the algorithms, errors in the treatment planning process, or improper use of output data, can represent a safety hazard to patients should the resulting output data be used for treatment purposes. This document defines requirements to be compliant with by manufacturers in the design and development of a radiotherapy treatment planning system in order to provide protection against the occurrence of such hazard
Scope: This document, with the inclusion of type tests and site tests, applies to the design, manufacture, installation, and maintenance of the radiotherapy treatment planning system. This document applies to the communication of the radiotherapy treatment planning system with other devices used in medical practice, that imports data either through input by the operator or from other devices, that outputs data to other devices, and that is intended to be for normal use, under the authority of appropriately qualified persons, by operators having the required skills and training, used and maintained in accordance with the recommendations given in the instructions for use, and used within the environmental conditions specified in the technical description. This document applies to any software application that is used for the development, evaluation, or approval of a treatment plan, whether stand-alone or part of another system. NOTE Such software applications include prescribing systems, image registration, contouring systems, quality assurance systems, plan analysis systems, or plan review systems.
Contents:
- FOREWORD
- INTRODUCTION
- Scope