IEC 62127-2-2025 PDF

IEC 62127-2-2025 PDF

Ultrasonics-Hydrophones-Part 2: Calibration for ultrasonic fields

$255.36 $510.71 -50%
Product Code: IEC 62127-2
Stock In Stock
Edition: 2.0
Published: 01/2025
Number of Pages: 238
File Size: 1 file, 5 Bytes

Available Options

Product Description

Ultrasonics – Hydrophones – Part 2: Calibration for ultrasonic fields

Introduction: The spatial and temporal distribution of acoustic pressure in an ultrasonic field in a liquid medium is commonly determined using miniature ultrasonic hydrophones. These devices are not absolute measurement instruments and it is important that they are calibrated. This part of IEC 62127 specifies the calibration methods to use in determining the response of a hydrophone in the ultrasonic range, i.e. above 50 kHz. The main hydrophone application in this context lies in the measurement of ultrasonic fields emitted by medical diagnostic equipment in water. It is important to understand hydrophone behaviour over a wide frequency band in order to reliably characterize the acoustic parameters of the applied acoustic field. In particular, the frequency range above 15 MHz is important to fully characterize this equipment, primarily due to the increased appearance of high-frequency components in the ultrasonic signals, caused by nonlinear propagation. In addition, the number of medical ultrasonic systems that use frequencies above 15 MHz, particularly intra-operative probes, is growing. It has turned out in recent years that the hydrophone response below 0,5 MHz is also important in order to reliably determine the peak-negative (rarefactional) acoustic pressure. While the term "hydrophone" can be used in a wider sense, it is understood here as referring to miniature piezoelectric hydrophones. It is this instrument type that is used today in various areas of medical ultrasonics and, in

Scope: This part of IEC 62127 specifies: absolute hydrophone calibration methods; relative (comparative) hydrophone calibration methods. Recommendations and references to accepted literature are made for the various relative and absolute calibration methods in the frequency range covered by this document. This document is applicable to hydrophones used for measurements made in water and in the ultrasonic frequency range 50 kHz to 100 MHz; NOTE 1 Although some physiotherapy medical applications of medical ultrasound are developing which operate in the frequency range 40 kHz to 100 kHz, the primary frequency range of diagnostic imaging remains above 2 MHz. It has recently been established that, even in the latter case, the hydrophone response at substantially lower frequencies can influence measurements made of key acoustic parameters [4]. NOTE 2 Calibration methods for underwater acoustics hydrophones applicable in the frequency range from 200 Hz to 1 MHz are available in IEC 60565-1 [2], and for frequencies from 0,01 Hz to several kilohertz in IEC 60565-2 [3]. hydrophones employing piezoelectric sensor elements, designed to measure the pulsed wave and continuous wave ultrasonic fields generated by ultrasonic equipment; NOTE 3 Some hydrophones can have non-circular active elements, arising from slight deviations from a circular structure caused, for example, by electrode structure; or, conversely, the active elements can actually be squares. It is important in these cases to pay special attention to the directional response and to the effective radii of the active element through various axes of rotation. hydrophones with or without a hydrophone pre-amplifier.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62127-2-2025 PDF

IEC 62127-2-2025 PDF

$255.36 $510.71