Calibration of wavelength/optical frequency measurement instruments-Part 2: Michelson interferometer single wavelength meters

$186.00 $371.99 -50%
Product Code: IEC 62129-2
Stock In Stock
Edition: 1.0
Published: 05/2011
Number of Pages: 102
File Size: 1 file, 622 Bytes

Available Options

Product Description

Calibration of wavelength/optical frequency measurement instruments – Part 2: Michelson interferometer single wavelength meters

Introduction: Wavelength meters, often based on the Michelson interferometer, are designed to measure the wavelength of an optical source as accurately as possible. Although the wavelength meters contain an internal absolute reference, typically a Helium-Neon laser, calibration is required to achieve the highest accuracies. The instrument is typically used to measure wavelengths other than that of the internal reference. Corrections are made within the instrument for the refractive index of the surrounding air. A precise description of the calibration conditions must therefore be an integral part of the calibration. This international standard defines all of the steps involved in the calibration process: establishing the calibration conditions, carrying out the calibration, calculating the uncertainty, and reporting the uncertainty, the calibration conditions and the traceability. The calibration procedure describes how to determine the ratio between the value of the input reference wavelength (or the optical frequency) and the wavelength meter's result. This ratio is called correction factor. The measurement uncertainty of the correction factor is combined following Annex A from uncertainty contributions from the reference meter, the test meter, the setup and the procedure. The calculations go through detailed characterization of individual uncertainties. It is important to know that: a) estimations of the individual uncertainties are acceptable; b) a detailed uncertainty analysis is only

Scope: This part of IEC 62129 is applicable to instruments measuring the vacuum wavelength or optical frequency emitted from sources that are typical for the fibre-optic communications industry. These sources include Distributed Feedback (DFB) laser diodes, External Cavity lasers and single longitudinal mode fibre-type sources. It is assumed that the optical radiation will be coupled to the wavelength meter by a single-mode optical fibre. The standard describes the calibration of wavelength meters to be performed by calibration laboratories or by wavelength meter manufacturers. This standard is part of the IEC 62129 series on the calibration of wavelength/optical frequency measurement instruments. Refer to IEC 62129 for the calibration of optical spectrum analyzers.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope