IEC 62236-5-2018 PDF

IEC 62236-5-2018 PDF

Railway applications-Electromagnetic compatibility-Part 5: Emission and immunity of fixed power supply installations and apparatus

$100.88 $201.76 -50%
Product Code: IEC 62236-5
Stock In Stock
Edition: 3.0
Published: 02/2018
Number of Pages: 46
File Size: 1 file, 1 Byte

Available Options

Product Description

Railway applications – Electromagnetic compatibility – Part 5: Emission and immunity of fixed power supply installations and apparatus

Introduction: The requirements of this part of IEC 62236 have been specified so as to ensure a level of electromagnetic emission which will cause minimal disturbance to other equipment. The levels, however, do not cover the following cases: a) which may occur with an extremely low probability of occurrence in any location; b) where highly susceptible apparatus is used in close proximity of the equipment covered by this document, in which case further measures may have to be taken. The emission limits given are on the basis that the equipment of the product family range is installed in traction substation areas.

Scope: This part of IEC 62236 applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this document since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment. If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirements in this document are not intended to be applicable to the intentional transmission from a radio- transmitter as defined by the ITU. The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. Emission and immunity limits are given for items of apparatus which are situated: a) within the boundary of a substation which delivers electric power to a railway; b) beside the track for the purpose of controlling or regulating the railway power supply, including power factor correction; c) along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection, and associated return conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage; d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. This category includes power supplies to marshalling yards, maintenance depots and stations; e) various other non-traction power supplies from railway sources which a

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62236-5-2018 PDF

IEC 62236-5-2018 PDF

$100.88 $201.76