IEC 62271-105-2021 PDF

IEC 62271-105-2021 PDF

High-voltage switchgear and controlgear-Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

$211.22 $422.43 -50%
Product Code: IEC 62271-105
Stock In Stock
Edition: 3.0
Published: 06/2021
Number of Pages: 110
File Size: 1 file, 1 Byte

Available Options

Product Description

High-voltage switchgear and controlgear – Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

Scope: This part of IEC 62271 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches composed of switches or switch-disconnectors and current-limiting fuses designed so as to be capable of breaking, at the rated voltage, any current up to and including the rated short-circuit breaking current; making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. It does not apply to combinations of fuses with circuit-breakers, contactors or circuit switchers, nor for combinations for motor-circuits nor to combinations incorporating single capacitor bank switches. This document applies to combinations designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. In this document, the word "combination" is used for a combination in which the components constitute a functional assembly. Each association of a given type of switch and a given type of fuse defines one type of switch-fuse combination. Different types of fuses can be combined with one type of switch, which give several combinations with different characteristics, in particular concerning the rated continuous currents. A switch-fuse combination is therefore defined by its type designation and a list of selected fuses defined by the manufacturer, the so-called "reference list of fuses". Compliance with this document of a given combination means that every combination using one of the selected fuses is proven to be in compliance with this document. The fuses are incorporated in order to extend the short-circuit breaking rating of the combination beyond that of the switch alone. They are fitted with strikers in order both to open automatically all three poles of the switch on the operation of a fuse and to achieve a correct operation at values of fault current above the minimum melting current but below the minimum breaking current of the fuses. In addition to the fuse strikers, the combination can be fitted with either an over-current release or a shunt release. NOTE In this document the term "fuse" is used to designate either the fuse or the

Contents:

  • FOREWORD
  • Scope
  • 3.101 Fuses
  • 5.101 Rated short-circuit breaking current
  • 5.102 Rated short-circuit making current
  • 5.103 Rated transfer current (striker operation) (Irtransfer)
  • 5.104 Rated take-over current for release-operated combinations (Irto)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62271-105-2021 PDF

IEC 62271-105-2021 PDF

$211.22 $422.43