IEC 62271-107 (REDLINE + STANDARD)-2019 PDF

IEC 62271-107 (REDLINE + STANDARD)-2019 PDF

High-voltage switchgear and controlgear-Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

$359.39 $718.77 -50%
Product Code: IEC 62271-107 (REDLINE + STANDARD)
Stock In Stock
Edition: 3.0
Published: 05/2019
Number of Pages: 176
File Size: 1 file, 2.9 MB

Available Options

Product Description

High-voltage switchgear and controlgear – Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

Introduction: Earthing switches forming an integral part of a circuit-switcher are covered by IEC 62271-102 [1]1. Installation in enclosure, if any, is covered either by IEC 62271-200 [2] or by IEC 62271-201 [3]. ______________ 1 Numbers in square brackets refer to the Bibliography.

Scope: Subclause 1.1 of IEC 62271-1:2007 is not applicable, and is replaced as follows. This part of IEC 62271 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of: breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current; making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. This part of IEC 62271 applies to three-pole-operated fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. They can be designed either as stand-alone devices, or be embedded in a switchgear and controlgear assembly. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Current-limiting fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher alone. NOTE 1 In this document, the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. This standard applies to fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. Comparison with other existing switching devices is provided in Clause 8. NOTE 2 Other circuit-switchers exist; see reference [4]. Devices that require a dependent manual operation are not covered by this document. Fuses are covered by IEC 60282-1. Earthing switches forming an integral part of a circuit-switcher are covered by IEC 6

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 3.101 Fuses
  • 5.101 Rated short-circuit breaking current (Isc)
  • 5.102 Rated short-circuit making current (Ima)
  • 5.103 Rated take-over current (Ito)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62271-107 (REDLINE + STANDARD)-2019 PDF

IEC 62271-107 (REDLINE + STANDARD)-2019 PDF

$359.39 $718.77