High-voltage switchgear and controlgear – Part 202: AC prefabricated substations for rated voltages above 1 kV and up to and including 52 kV
Introduction: A prefabricated substation is defined as a high-voltage type-tested assembly comprising an enclosure containing at least a power transformer and/or a high-voltage switchgear and controlgear, and, in general, all or some of the following main components: low-voltage switchgear and controlgear, electrical high-voltage interconnection and low-voltage interconnection. The prefabricated substation can include all necessary auxiliary and control equipment for its operation. The purpose being to supply low-voltage power from a high-voltage system and/or vice versa (high-voltage/low-voltage transformer substation) or distribute electric power in a high-voltage network (high-voltage switchgear substation). These prefabricated substations can be in locations accessible to the public and should ensure protection not only to authorized persons but also to general public under the specified service conditions. Therefore, in addition to the specified characteristics, ratings and relevant test procedures, particular attention has been paid to the specification concerning the protection of persons, both operators and general public. Use of type-tested components and suitable design and construction of the assembly contributes to this protection. The correct design and performance of the prefabricated substation is verified by means of relevant type and routine tests described in this document, including internal arc tests (if applicable).
Scope: This part of IEC 62271 specifies the service conditions, rated characteristics, general structural requirements and test methods of enclosed high-voltage prefabricated substations. These prefabricated substations are cable-connected to AC high-voltage networks with an operating voltage up to and including 52 kV and power frequencies up to and including 60 Hz. They can be manually operated from inside (walk-in type) or from outside (non-walk-in type). They are designed for outdoor installation at locations with public accessibility and where protection of personnel is provided. These prefabricated substations can be situated at ground level or partially or completely below ground level. The last are also called "underground prefabricated substations". In general, two types of prefabricated substations are considered in this document: high-voltage switchgear prefabricated substations; high-voltage/low-voltage transformer prefabricated substations (step-up and step-down). A high-voltage switchgear prefabricated substation comprises an enclosure containing in general the following electrical components: high-voltage switchgear and controlgear; auxiliary equipment and circuits. A high-voltage/low-voltage transformer prefabricated substation comprises an enclosure containing in general the following electrical components: power transformer(s); high-voltage and low-voltage switchgear and controlgear; high-voltage and low-voltage interconnections; auxiliary equipment and circuits. However, relevant provisions of this document are applicable to designs where not all these electrical components exist (for example, a prefabricated substation consisting of power transformer and low-voltage switchgear and controlgear). The listed electrical components of a high-voltage/low-voltage transformer prefabricated substation can be incorporated in the prefabricated substation either as separate components or as an assembly type CEADS according to IEC 62271-212. This document covers only designs using natural ventilation. However, relevant provisions of this document are applicable to designs using other means of ventilation except the rated power of the prefabricated substation and
Contents:
- FOREWORD
- INTRODUCTION
- Scope