IEC 62271-214-2024 PDF

IEC 62271-214-2024 PDF

High-voltage switchgear and controlgear-Part 214: Internal arc classification for AC metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

$163.93 $327.86 -50%
Product Code: IEC 62271-214
Stock In Stock
Edition: 2.0
Published: 04/2024
Number of Pages: 72
File Size: 0 files

Available Options

Product Description

High-voltage switchgear and controlgear – Part 214: Internal arc classification for AC metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

Introduction: IEC 62271-214 has been developed due to the requirement to remove IAC Type C designated pole-mounted switchgear from IEC 62271-200. IEC 62271-214 is to be considered independent of IEC 62271-200, however it is still related to other product standards of the IEC 62271 series. Only open terminal pole-mounted switchgear and controlgear has been considered within this document. This equipment relates to operation in three-phase, two-phase and single-phase systems.

Scope: This part of IEC 62271 specifies requirements for internal arc classification of AC metal- enclosed pole-mounted switchgear and controlgear with rated voltages above 1 kV and up to and including 52 kV with service frequencies up to and including 60 Hz. This document is applicable to three-phase, two-phase and single-phase open terminal equipment for which an internal arc classification is assigned. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. NOTE 1 The IAC classification takes into account the installation disposition of the high-voltage switchgear and controlgear and worker's operating area. NOTE 2 For the use of this document, high-voltage (IEC 60050-601:1985, 601-01-27) is the rated voltage above 1 000 V. However, medium voltage (IEC 60050-601:1985, 601-01-28) is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV; refer to [1]1. This document does not preclude that other equipment may be included in the same enclosure. In such a case, any possible influence of that equipment on the switchgear and controlgear is to be taken into account.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 5.101 Ratings of the internal arc classification (IAC)
  • 6.101 Internal arc fault
  • 6.102 Enclosure
  • 7.101 Internal arc type test
  • 9.101 Internal arc fault