Protection against lightning-Part 1: General principles

$239.59 $479.18 -50%
Product Code: IEC 62305-1
Stock In Stock
Edition: 3.0
Published: 09/2024
Number of Pages: 158
File Size: 1 file, 5 Bytes

Available Options

Product Description

Protection against lightning – Part 1: General principles

Introduction: There are no devices or methods capable of modifying the natural weather phenomena to the extent that they can prevent lightning discharges. Lightning flashes to, or nearby, structures (or lines connected to the structures) are hazardous to people, to the structures themselves, their contents and installations as well as to lines. This is why the application of lightning protection measures is essential. The need for protection, the economic benefits of installing protection measures, and the selection of adequate protection measures should be determined in terms of risk management. Risk management is the subject of IEC 62305-2 [2]. NOTE In Germany, the need for lightning protection is determined by, and the class of required LPS shall be selected according to, a national annex to the third edition of IEC 62305-1 (including an option for a risk assessment following the third edition of IEC 62305-2). Protection measures considered in the IEC 62305 series have been proven to be effective in risk reduction. All measures for protection against lightning form the overall lightning protection. For practical reasons the criteria for design, installation and maintenance of lightning protection measures are considered in two separate groups: the first group concerning protection measures to reduce physical damage and life hazard in a structure is given in IEC 62305-3; the second group concerning protection measures to reduce failures of electrical and electronic systems in a structure

Scope: This part of IEC 62305 provides general principles for the protection of structures against lightning, including their installations and contents, as well as persons. The following cases are outside the scope of this document: railway systems; vehicles, ships, aircraft, offshore installations; underground high-pressure pipelines; pipe, power and telecommunication lines separated from the structure; nuclear power plants. The IEC 62305 series should be considered as a minimum requirement for these structures. Until any further information by CIGRE is available the lightning current parameters described in this document can be applied also for offshore installations. NOTE 1 In these cases, structures usually fall under special regulations produced by various specialized authorities. For structures (subsidiary or others) not falling under such special regulations, the IEC 62305 series still applies. NOTE 2 Lightning protection of wind turbines is also covered by IEC 61400-24 [4].

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62305-1-2024 PDF

IEC 62305-1-2024 PDF

$239.59 $479.18