Protection against lightning – Part 3: Physical damage to structures and life hazard
Introduction: This part of IEC 62305 deals with the protection, in and around a structure, against physical damage and injury to human beings due to touch and step voltages. The main and most effective measure for protection of structures and its content against physical damage is considered to be a lightning protection system (LPS). It usually consists of both external and internal lightning protection measures. An external LPS is intended to a) intercept a lightning flash to the structure (with an air-termination system), b) conduct the lightning current safely towards earth (using a down-conductor system), c) disperse the lightning current into the earth (using an earth-termination system). NOTE The purpose of the external LPS is to protect the structure from a direct lightning strike by providing the preferred attachment points, conducting and dispersing the lightning current. It will not significantly influence the attachment process between the structure and the lightning to increase or reduce the number of direct lightning strikes (S1) to the structure. An internal LPS prevents dangerous sparking within the structure using either equipotential bonding or a separation distance (and hence isolation) between the external LPS (as defined in 3.2) and other electrically conducting elements internal to the structure. Main protection measures against injury to human beings due to touch and step voltages are intended to: 1) reduce dangerous current flowing through bodies by either insulating
Scope: This part of IEC 62305 provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to human beings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1). This document is applicable to the: a) design, installation, inspection and maintenance of an LPS for structures without limitation of their height, b) establishment of measures for protection against injury to human beings primarily due to touch and step voltages. NOTE 1 Specific requirements for an LPS in structures dangerous to their surroundings due to the risk of explosion are provided in Annex C. NOTE 2 This document is not intended to provide protection against failures of electrical and electronic systems due to overvoltages. Specific requirements for such cases are provided in IEC 62305-4. NOTE 3 Specific requirements for the protection against lightning of wind turbines are reported in IEC 6140024 [1]1. NOTE 4 Specific requirements for the protection against overvoltage of photovoltaic systems are reported in IEC 61643-32 [2] and in IEC 62305-4:2024, Annex F.
Contents:
- FOREWORD
- INTRODUCTION
- Scope