Determination of certain substances in electrotechnical products – Part 10: Polycyclic aromatic hydrocarbons (PAHs) in polymers and electronics by gas chromatography-mass spectrometry (GC-MS)
Introduction: The widespread use of electrotechnical products has drawn increased attention to their impact on the environment. In many countries this has resulted in the adoption of regulations affecting wastes, substances and energy use of electrotechnical products. The use of certain substances (e.g. lead (Pb), cadmium (Cd) and polybrominated diphenyl ethers (PBDEs)) in electrotechnical products is a source of concern in current and proposed regional legislation. The purpose of the IEC 62321 series is therefore to provide test methods that will allow the electrotechnical industry to determine the levels of certain substances of concern in electrotechnical products on a consistent global basis. This first edition of IEC 62321-10 introduces a new subject covering polycyclic aromatic hydrocarbons (PAHs) in the IEC 62321 series. WARNING – Persons using this document should be familiar with normal laboratory practice. This document does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to ensure compliance with any national regulatory conditions.
Scope: This part of IEC 62321 specifies one normative technique for the determination of polycyclic aromatic hydrocarbons (PAHs) in polymers of electrotechnical products. These PAHs can especially be found in the plastic and rubber parts of a wide range of consumer articles. They are present as impurities in some of the raw materials used in the production of such articles, in particular in extender oils and in carbon black. They are not added intentionally to the articles and do not perform any specific function as constituents of the plastic or rubber parts. The gas chromatography-mass spectrometry (GC-MS) test method is suitable for the determination of polycyclic aromatic hydrocarbons (PAHs). These test methods have been evaluated for use with plastics and rubbers. These test methods have been evaluated for use with ABS (acrylonitrile butadiene styrene) containing individual PAHs ranging from 37,2 mg/kg to 119 mg/kg and rubbers containing individual PAHs ranging from 1 mg/kg to 221,2 mg/kg. WARNING – This document does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This horizontal standard is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 108. One of the responsibilities of a technical committee is, wherever applicable, to make use of horizontal standards in the preparation of its publications. The contents of this horizontal standard will not apply unless specifically referred to or included in the relevant publications.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 10 Precision: repeatability and reproducibility
- 11 Quality assurance and control
- 12 Test report