IEC 62369-1-2008 PDF

IEC 62369-1-2008 PDF

Evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range 0 GHz to 300 GHz-Part 1: Fields produced by devices used for electronic article surveillance, radio frequency identification and similar systems

$239.59 $479.18 -50%
Product Code: IEC 62369-1
Stock In Stock
Edition: 1.0
Published: 08/2008
Number of Pages: 154
File Size: 1 file, 9 Bytes

Available Options

Product Description

Evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range 0 GHz to 300 GHz – Part 1: Fields produced by devices used for electronic article surveillance, radio frequency identification and similar systems

Introduction: Electromagnetic fields interact with the human body and other biological systems through a number of physical mechanisms. The main mechanisms of interaction are based on nervous system effects and heating. These effects are dependent on frequency and are defined by biologically relevant quantities. Based on these scientifically established health effects, there are international, regional and sometimes national exposure requirements. These are set as basic restrictions on quantities, which are not necessarily directly measurable, and contain high safety factors to ensure a high level of protection. These quantities may be determined either by calculation for each case, or by measuring a reference value that has a pre-derived relationship to them, usually under worst-case, far-field conditions. Respect of the reference value will ensure respect of the relevant basic restriction, except in some specific near field situations which would normally be identified or highlighted within the applicable exposure guidelines. If the measured quantity exceeds the reference value, it does not necessarily follow that the basic restriction is also exceeded. Under those circumstances, more detailed evaluation techniques will be necessary which are specific to that type of equipment and exposure. This document is part of a multi-part standard covering the evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range from

Scope: This part of IEC 62369 presents procedures for the evaluation of human exposure to electromagnetic fields (EMFs) from devices used in electronic article surveillance (EAS), radio frequency identification (RFID) and similar applications. It adopts a staged approach to facilitate compliance assessment. The first stage (Stage 1) is a simple measurement against the appropriate derived reference values. Stage 2 is a more complex series of measurements or calculations, coupled with analysis techniques. Stage 3 requires detailed modelling and analysis for comparison with the basic restrictions. When assessing any device, the most appropriate method for the exposure situation may be used. At the time of writing this International Standard, electronic article surveillance, radio frequency identification and similar systems do not normally operate at frequencies below 1 Hz or above 10 GHz. EMF exposure guidelines and standards can cover a wider range of frequencies, so clarification on the required range is included as part of the evaluation procedures. The devices covered by this document normally have non-uniform field patterns. Often these devices have a very rapid reduction of field strength with distance and operate under near- field conditions where the relationship between electric and magnetic fields is not constant. This, together with typical exposure conditions for different device types, is detailed in Annex A. Annex B contains comprehensive information to assist with numerical modelling of the exposure situation. It includes both homogeneous and anatomical models as well as the electrical properties of tissue. This International Standard does not include limits. Limits can be obtained from separately published human exposure guidelines. Different guidelines and limit values may apply in different regions. Linked into the guidelines are usually methods for summation across wider frequency ranges and for multiple exposure sources. These shall be used. A simplified method for summation of multiple sources is contained in Annex C. This has to be used with care as it is simplistic and will overestimate the exposure; however it is useful as a guide, when the result

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • Introduction

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62369-1-2008 PDF

IEC 62369-1-2008 PDF

$239.59 $479.18