IEC 62387-2020 PDF

IEC 62387-2020 PDF

Radiation protection instrumentation-Dosimetry systems with integrating passive detectors for individual, workplace and environmental monitoring of photon and beta radiation

$239.59 $479.18 -50%
Product Code: IEC 62387
Stock In Stock
Edition: 2.0
Published: 01/2020
Number of Pages: 184
File Size: 1 file, 3 Bytes

Available Options

Product Description

Radiation protection instrumentation – Dosimetry systems with integrating passive detectors for individual, workplace and environmental monitoring of photon and beta radiation

Introduction: A dosimetry system may consist of the following elements: a) a passive device, referred to herein as a detector, which, after the exposure to radiation, stores a signal for use in measuring one or more quantities of the incident radiation field; b) a “dosemeter”, that incorporates some means of identification and contains one or more detectors and may contain electronic components, e.g. for the readout (e.g., in a direct ion storage (DIS) dosemeter); c) a “reader” which is used to readout the stored information (signal) from the detector, in order to determine the radiation dose; d) a “computer” with appropriate “software” to control the reader, store the signals transmitted from the reader, calculate, display and store the evaluated dose in the form of an electronic file or paper copy; e) “additional equipment” and documented procedures (instruction manual) for performing associated processes such as deleting stored dose information, cleaning dosemeters, or those needed to ensure the effectiveness of the whole system.

Scope: This document applies to all kinds of passive dosimetry systems that are used for measuring: the personal dose equivalent Hp(10) (for individual whole body monitoring), the personal dose equivalent Hp(3) (for individual eye lens monitoring), the personal dose equivalent Hp(0,07) (for both individual whole body skin and local skin for extremity monitoring), the ambient dose equivalent H*(10) (for workplace and environmental monitoring), the directional dose equivalent H'(3) (for workplace and environmental monitoring), or the directional dose equivalent H'(0,07) (for workplace and environmental monitoring). This document applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in Table 1. All the energy values are mean energies with respect to the fluence. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled. Table 1 – Mandatory and maximum energy ranges covered by this document Measuring quantity Mandatory mean energy range for photon radiation Maximum mean energy range for testing photon radiation Mandatory mean energy range for beta-particle radiationa Maximum mean energy range for testing beta- particle radiationa Hp(10), H*(10) 80 keV to 1,25 MeVb 12 keV to 7 MeV Hp(3), H'(3) 30 keV to 250 keV 8 keV to 7 MeV 0,8 MeVc 0,7 MeVc to 1,2 MeV Hp(0,07), H'(0,07) 30 keV to 250 keV 8 keV to 1,25 MeVb 0,24 MeV to 0,8 MeV 0,07 MeVd to 1,2 MeVe The following beta radiation sources are suggested for the different mean energies: For 0,06 MeV: 147Pm; for 0,8 MeV: 90Sr/90Y; for 1,2 MeV: 106Ru/106Rh. 1,25 MeV is the mean energy of photon radiation from 60Co. For beta-particle radiation, an energy of 0,7 MeV is required to reach the radiation sensitive layers of the eye lens in a depth of about 3 mm (approximately 3 mm of ICRU tissue). For beta-particle radiation, an energy of 0,07 MeV is required to penetrate the dead layer of skin of 0,07 mm (approximately 0,07 mm of ICRU tissue). 0,07 MeV, 0,8 MeV and 1,2 MeV beta mean energy are almost equivalent to an Emax of 0,225 MeV, 2,27 MeV and 3,54 MeV, respectively. NOTE

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.