Radiation protection instrumentation – Alarming personal radiation devices (PRDs) for the detection of illicit trafficking of radioactive material
Introduction: Illicit and inadvertent movement of radioactive materials has become a problem of increasing importance. Radioactive sources out of regulatory control, so-called “orphan sources”, have frequently caused serious radiation exposures and widespread contamination. Although illicit trafficking in nuclear and other radioactive materials is not a new phenomenon, concern about a nuclear “black market” has increased in the last few years, particularly in view of its terrorist potential. In response to the technical policy of the International Atomic Energy Agency (IAEA), the World Customs Organization (WCO) and the International Criminal Police Organization (Interpol) related to the detection and identification of special nuclear materials and security trends, nuclear instrumentation companies are developing and manufacturing radiation instrumentation to assist in the detection of illicit movement of radioactive and special nuclear materials. This type of instrumentation is widely used for security purposes at nuclear facilities, border control checkpoints, and international seaports and airports. However, to ensure that measurement results made at different locations are consistent, it is imperative that radiation instrumentation be designed to rigorous specifications based upon agreed performance requirements stated in international standards. Several IEC standards have been developed to address body-worn, hand-held and portal instruments, see Table 1. Table 1 – IEC standards concer
Scope: This document applies to alarming radiation detection instruments that are pocket-sized, carried on the body and used to detect and indicate the presence and general magnitude of gamma radiation fields. Neutron detection may also be provided. Personal Radiation Devices (PRDs) alert the user to the presence of a source of radiation that is distinctly above the measured average local background radiation level. They are not intended to provide a measurement of the ambient or personal dose equivalent rate. The object of this document is to describe design and functional criteria along with testing methods for evaluating the performance of the PRDs used for detection of illicit trafficking of radioactive material (e. g., for border radiation monitoring). This document does not apply to the ambient or personal dose equivalent rate meters which are covered in IEC 60846-1 or IEC 61526, respectively. If the manufacturer states that the PRD can be used for radiation protection purposes, compliance with IEC 60846-1 or IEC 61526 will be needed.
Contents:
- FOREWORD
- INTRODUCTION
- Scope