Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses

$163.93 $327.86 -50%
Product Code: IEC 62423
Stock In Stock
Edition: 2.0
Published: 11/2009
Number of Pages: 78
File Size: 0 files

Available Options

Product Description

Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses

Introduction: RCCBs and RCBOs designed according to IEC 61008-1 and IEC 61009-1 are suitable in most of the applications. IEC 61008-1 and 61009-1 provide appropriate requirements and tests for general use in household and similar uses. However, the use of new electronic technology in equipment may result in particular residual currents not covered in IEC 61008-1 or IEC 61009-1. This standard covers specific applications where additional requirements and testing are needed. This standard includes definitions, additional requirements and tests for Type F and Type B RCCBs and/or RCBOs to cover particular situations. The tests shall first be applied according to IEC 61008-1 for Type F or Type B RCCBs and according to IEC 61009-1 for Type F or Type B RCBOs. After completion of the tests given either in IEC 61008-1 or IEC 61009-1 the additional tests given in this standard shall be applied in order to show conformity to this standard (see Annex A, Annex B for Type F or Annex C, Annex D for Type B respectively). The number of samples to be submitted and test sequences to be applied for verification of conformity for Type F RCCBs and Type F RCBOs are given in Annex A and Annex B respectively. The number of samples to be submitted and test sequences to be applied for verification of conformity for Type B RCCBs and Type B RCBOs are given in Annex C and Annex D respectively. This standard introduces Type F RCDs (F for Frequency) with rated frequency 50 Hz or 60 Hz intended for protection of circuits

Scope: The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. This standard specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residual current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1. Type F RCCBs (Residual Current Circuit Breaker) and Type F RCBOs (Residual current Circuit Breaker with Overcurrent protection) with rated frequency 50 Hz or 60 Hz are intended for installations when frequency inverters are supplied between phase and neutral or phase and earthed middle conductor and are able to provide protection in case of alternating residual sinusoidal at the rated frequency, pulsating direct residual currents and composite residual currents that may occur. Type B RCCBs and Type B RCBOs are able to provide protection in case of alternating residual sinusoidal currents up to 1 000 Hz, pulsating direct residual currents and smooth direct residual currents. RCDs according to this standard are not intended to be used in d.c. supply systems. Further requirements and tests for products to be used in situations where the residual current was not intended to be covered in IEC 61008-1 or IEC 61009-1 are under consideration. For the purpose of manufacturer’s declaration or verification of conformity, type tests should be carried out in test sequences in compliance with Annex A, Annex B, Annex C or Annex D of this standard. The complete test sequence for type test of Type F RCCBs and Type F RCBOs is given in Tables A.1 and B.1 respectively. The complete test sequence for type test of Type B RCCBs and Type B RCBOs is given in Tables C.1 or D.1 respectively. NOTE 1 Throughout the document, the term RCD refers to RCCBs and RCBOs. NOTE 2 Requirements for 1 pole with solid neutral are under consideration. NOTE 3 Type F and type B RCDs have high resistance against unwanted tripping, even if the surge voltage causes a flashover and a follow-on current occurs, and in case of inrush residual currents with a maximum duration of 10 ms which can occur in case of switching ON electronic equipment or

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope