Railway applications – Insulation coordination – Part 1: Basic requirements – Clearances and creepage distances for all electrical and electronic equipment
Introduction: Special conditions occurring in railway applications and the fact that the equipment here concerned falls into the scope of both IEC 60071 (prepared by IEC technical committee 28) and IEC 60664-1 (prepared by IEC technical committee 109), led to the decision to draw from these documents and from IEC 60077-1 (prepared by IEC technical committee 9), a single document of reference for all standards applicable to the whole railway field. IEC 62497 consists of two parts: IEC 62497-1: Part 1: Basic requirements – Clearances and creepage distances for all electrical and electronic equipment; IEC 62497-2: Part 2: Overvoltages and related protection. This Part 1 allows, in conjunction with IEC 62497-2, to take into account advantages resulting from the presence of overvoltage protection when dimensioning clearances.
Scope: This part of IEC 62497 deals with insulation coordination in railways. It applies to equipment for use in signalling, rolling stock and fixed installations up to 2 000 m above sea level. Insulation coordination is concerned with the selection, dimensioning and correlation of insulation both within and between items of equipment. In dimensioning insulation, electrical stresses and environmental conditions are taken into account. For the same conditions and stresses these dimensions are the same. An objective of insulation coordination is to avoid unnecessary overdimensioning of insulation. This standard specifies: requirements for clearances and creepage distances for equipment; general requirements for tests pertaining to insulation coordination. The term equipment relates to a section as defined in 3.3; it may apply to a system, a sub- system, an apparatus, a part of an apparatus, or a physical realisation of an equipotential line. This standard does not deal with : distances through solid or liquid insulation; distances through gases other than air; distances through air not at atmospheric pressure; equipment used under extreme conditions. Product standards have to align with this generic standard. However, they may require, with justification, different requirements due to safety and/or reliability reasons, e.g. for signalling, and/or particular operating conditions of the equipment itself, e. g. overhead lines which have to comply to established standards or regulations such as EN 50119. This standard also gives provisions for dielectric tests (type tests or routine tests) on equipment (see Annex B). NOTE For safety critical systems, specific requirements are needed. These requirements are given in the product specific signalling standard IEC 62425.
Contents:
- FOREWORD
- INTRODUCTION
- Scope