Ultrasonics – Power measurement – High intensity therapeutic ultrasound (HITU) transducers and systems
Introduction: In ultrasound fields at megahertz frequencies, output power is typically determined by measuring the force on a target using a radiation force balance [1],[2],[3]. However, the relationship between the radiation force and the output power is affected by the focusing or other geometrical aspects of the field, by the type and shape of the target, by the distance of the target from the transducer, by absorption (including ‘shock-loss’) in the water path, and by acoustic streaming currents. Whilst many of these effects are small for typical diagnostic or physiotherapy ultrasound fields, they cannot generally be ignored for HITU fields (particularly for those often referred to as high intensity focused ultrasound HIFU) [4]. Furthermore, in HITU, the quantity of interest is the power incident on the patient rather than the output power at the transducer face. Since it is common to have a water stand-off between the transducer and the patient, attenuation and shock-loss in the water path may be significant and will vary depending upon the chosen distance. The purpose of this International Standard is to establish standard methods of measurement of ultrasonic power of HITU devices in liquids in the lower megahertz frequency range based on the measurement of the radiation force using a gravimetric balance, and calorimetry (based on the measurement of thermal expansion). This standard identifies the sources of errors and describes a systematic step-by-step procedure to assess overall m
Scope: This International Standard establishes general principles relevant to HITU fields for the use of radiation force balances in which an obstacle (target) intercepts the sound field to be measured; specifies a calorimetric method of determining the total emitted acoustic power of ultrasonic transducers based on the measurement of thermal expansion of a fluid-filled target; specifies requirements related to the statement of electrical power characteristics of ultrasonic transducers; provides guidance related to the avoidance of acoustic cavitation during measurement; provides guidance related to the measurement of HITU transducers of different construction and geometry, including collimated, diverging and convergent transducers, and multi-element transducers; provides guidance on the choice of the most appropriate measurement method; provides information on assessment of overall measurement uncertainties. This International Standard is applicable to the measurement of ultrasonic power generated by HITU equipment up to 500 W in the frequency range from 0,5 MHz to 5 MHz. HITU equipment may generate convergent, collimated or divergent fields. For frequencies less than 500 kHz, no validations exist and the user should assess the uncertainties of the power measurement and measurement system at the frequencies of operation. This International Standard does not apply to: ultrasound equipment used for physiotherapy, for lithotripsy for general pain relief.
Contents:
- FOREWORD
- INTRODUCTION
- Scope