Railway applications – Fixed installations – Electric traction – Specific requirements for composite insulators used for overhead contact line systems
Introduction: This standard specifies requirements for the design and testing of composite insulators used on railway electric traction overhead contact line systems. Such insulators, which are installed at relatively low heights in the harsh environment of railway infrastructures, require specific considerations during design to reduce the effects of vandalism and environmental pollution from railway operations, especially when combined with a lack of natural washing. Insulators may be included in arrangements in tunnels and over bridges or be in contact with traction unit pantographs where combined mechanical loading (tension, bending and torsion) may require special consideration. The standard is intended to allow the manufacturer to comply with local working practices, to ensure compatibility with existing electric traction overhead contact line systems, and provide an insulator which will give reliable service over its target life span with minimum maintenance. Insulators intended for overhead lines are predominately designed to resist tension and/or bending loads and are not designed to resist torsional loads. Mitigating measures to reduce torsional loading are generally introduced by the overhead contact lines design engineer. Some combined loading (tension, compression and torsion) can be experienced and this is represented in the testing procedure specified in this document. The testing procedures given for railway applications in this standard are predominately referenced from IE
Scope: This International Standard specifies characteristics for composite insulators of electric traction overhead contact line systems for railways, as defined in IEC 60913. Insulators specified in this standard are applied for electric traction supply voltages with a nominal voltage greater than 1 000 V for a.c. or a nominal voltage greater than 1 500 V for d.c.. Specific applications where high torsional loads can occur are outside the scope of this standard and particular tests are agreed between the supplier and customer to represent the critical loading arrangements. This International Standard applies to composite insulators as defined in 3.1 below and not to other polymeric insulators. The provisions contained in this standard are intended for the design and construction of new electric traction overhead contact line systems using insulators, or when complete refurbishment of existing overhead contact line systems takes place. This standard provides the purchaser and manufacturer with a range of tests which are used to evaluate the suitability of an insulator product for a given railway environment. Additional tests may be specified by the client to measure the compliance of the insulator under particular operating conditions. The standard establishes the product characteristics, the test methods and acceptance criteria. The object of this standard is to stipulate the provisions for the design and provision of the service indicated by the manufacturer to the customer or informed buyer for application on the railway infrastructure.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 4.10 In-running insulators