Measurement procedures for materials used in photovoltaic modules – Part 1-7: Encapsulants – Test procedure of optical durability
Introduction: IEC 61215-2 (covering module design qualification and type approval) specifies a UV preconditioning of 54 MJ⋅m-2 (15 kWh⋅m-2), which would be encountered after ~40 ideal sunny days of exposure to the AM1.5G UV spectrum in IEC 60904-3. IEC 61730-2 presently specifies 4x the same UV exposure, i.e., 5 months UV dose. The International PV Quality Assurance Task Force (PVQAT) leads global efforts to craft quality and reliability standards for solar energy technologies. These standards will allow stakeholders to quickly assess a solar photovoltaic (PV) module's performance and ability to withstand weather stresses, thereby reducing risk and adding confidence for those developing products, designing incentive programs, and determining private investments. As developed in conjunction with PVQAT, this part of IEC 62788-1 is intended to supplement module qualification, which typically covers reliability issues related to infant mortality, i.e., the first months of field use. This part of IEC 62788-1 may also facilitate the pre-qualification of encapsulation materials using coupon specimens, because long term weathering is not practical for larger module specimens. This part of IEC 62788-1 also importantly uses high fidelity UV irradiation (relative to the terrestrial solar spectrum), which is not practical to apply to module specimens (due to the lack of available commercial equipment and the anticipated cost of operation).This part of IEC 62788-1 is not presently specified for pre-qua
Scope: IEC 61215-2 provides a set of qualification tests that indicate that a PV module design is likely to be free of flaws that will result in early failure. However, IEC 61215-2 does not address the long term wear-out of PV modules. This part of IEC 62788-1 is designed as a more rigorous qualification test, using accelerated UV exposure at elevated temperature to determine whether polymeric encapsulants can suffer loss of optical transmittance. IEC 61215-2 already includes a UV preconditioning test (MQT 10), however, the parameters for that test only represent a limited level of exposure (~weeks of UV dose). This test procedure is intended for representative coupon specimens, applying stress at a greater intensity (designed relative to Phoenix, AZ), using a radiation spectrum that is more similar to the terrestrial solar spectrum, and using a duration of exposure that is more relevant to the PV application (i.e., equivalent to several years of outdoor exposure). This test quantifies the degradation rate of encapsulants so that the risk of the materials losing optical transmittance during operation in the terrestrial environments can be managed. The quantitative correlation between climate (or location of use), a specific application (utility-installation, residential-installation, roof-mount, rack-mount, use of a tracker, the system electrical configuration and its operation), and the test can be established for each specific encapsulant material, but is beyond the scope of this document. The method herein is intended to qualify encapsulants for use in a PV module. This document is intended to apply to encapsulants used in PV modules deployed under temperature conditions of normal use, as defined in IEC TS 63126. The use of this method for encapsulants in modules deployed under conditions of higher temperature is specified elsewhere, for example IEC TS 63126. The method here is intended to be used to examine a particular encapsulant and does not cover incompatibilities between the encapsulant and other packaging materials. This document covers PV technology constructed using transparent incident surface/encapsulant/photovoltaic device construction, the relevance to
Contents:
- FOREWORD
- INTRODUCTION
- Scope