Particular requirements for source switching equipment (SSE)
Introduction: The optimization of electrical energy usage can be facilitated by appropriate design and installation considerations. An electrical installation can provide the required level of service and safety for the lowest level of electrical consumption. This is considered by designers as a general requirement of their design procedures to establish the best use of electrical energy. The optimization of the use of electricity is based on energy efficiency management taking into consideration the price of electricity, electrical consumption of the loads and real-time adaptation, as described in Figure 1, which is reproduced from IEC 60364-8-1:2019, Figure 1. Figure 1 – Energy efficiency management system (EEMS) This document applies to source switching equipment (SSE), for household and similar uses (see Figure 2).
Scope: This International Standard applies to source switching equipment, hereafter referred to as SSE, for household and similar uses, primarily intended to be used for energy efficiency (EE) purposes with local production and/or storage of energy. SSE is intended to be installed in low voltage prosumer electrical installations (PEI) to deliver the electrical energy: either to current-using equipment (direct feeding mode or island mode); or to the grid (reverse feeding mode). SSE is intended to select and/or combine two power sources (e.g. selected from among grid, local power source, storage units) within an electrical energy management system (EEMS). SSE can also be used for backup supply. NOTE 1 "Switching device for islanding" (SDFI) function is under consideration as additional requirements can be necessary. See also Figure 4 of IEC 60364-8-82:2022. SSE is part of the fixed electrical installation. This document applies to SSE for operation in AC single or multiphase main circuits with rated voltages not exceeding 440 V AC, frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A (40 A for screwless terminals). They are intended to be used in installations with prospective short circuit currents not exceeding 25 000 A. DC operations are not covered by this edition and are kept under consideration for a future revision of this document. According to this document, SSE can be operated: manually (M-SSE), or remotely (R-SSE), or automatically (A-SSE), or a combination of the above methods of operation, e.g. manual and remote. SSE is used to select two sources sequentially. SSE able to run two (or more) sources in parallel are not covered by this edition and are kept under consideration for a future revision of this product standard. SSE can be operated with interlocks and/or synchronization. NOTE 2 In some countries, it is not permitted to have synchronization of local sources with the grid for particular grid conditions, e.g. when fluctuations of the grid voltage or frequency are outside the tolerance limits. SSE is constructed either as combined SSE (C-SSE, based on dedicated products such as circuit breakers, switches or contactors) or non-co
Contents:
- FOREWORD
- INTRODUCTION
- Scope