IEC 63027-2023 PDF

IEC 63027-2023 PDF

Photovoltaic power systems-DC arc detection and interruption

$239.59 $479.18 -50%
Product Code: IEC 63027
Stock In Stock
Edition: 1.0
Published: 05/2023
Number of Pages: 136
File Size: 1 file, 5 Bytes

Available Options

Product Description

Photovoltaic power systems – DC arc detection and interruption

Introduction: This document provides requirements and testing procedures for arc-fault protection devices used in PV systems to reduce the risk of igniting an electrical fire. A PV system contains a number of distributed DC sources (PV modules) and circuits. In AC systems series arc durations are limited by the alternating current crossing through zero ampere twice per cycle. In DC systems the arcing current may be constant and longer arc durations are expected. In contrast to a centralized power supply, where in case of a fault the circuit is disconnected at the connection to the supply, a PV system is made up of distributed power supplies which cannot disconnect circuits in a single location. For extinguishing series arcs, however, the location of the arc within the circuit is irrelevant as long as the current is interrupted. This arc fault protection may be located inside the inverter, on array circuits, subarray circuits, string circuits, or at the module level. Therefore, this document provides a range of test setups to cover the expected system topologies. In PV systems earth fault protection is required according to the IEC installation standards. Moreover, single core cables with double or reinforced insulation are required (except ELV systems). Consequently, the risk of parallel arcs is quite low because in most cases an earth fault occurs first. As such, this document does not address requirements or testing for parallel arc detection. The larger risk for PV systems comes from se

Scope: This document applies to equipment used for the detection and optionally the interruption of electric DC arcs in photovoltaic (PV) system circuits. The document covers test procedures for the detection of series arcs within PV circuits, and the response times of equipment employed to interrupt the arcs. The document defines reference scenarios according to which the testing is conducted. This document covers equipment connected to systems not exceeding a maximum PV source circuit voltage of 1 500 V DC. The detection of parallel circuit arcs is not covered in this document. This document is not applicable to DC sources or applications other than PV DC sources. NOTE Parallel arc detection may be considered for a future edition.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.