Conversion method of specific absorption rate to absorbed power density for the assessment of human exposure to radio frequency electromagnetic fields from wireless devices in close proximity to the head and body – Frequency range of 6 GHz to 10 GHz
Introduction: This document provides the method to conservatively evaluate the area averaged electromagnetic (EM) power density entering the human body, i.e. the absorbed power density (APD), for communication devices intended to be used at a position near the human head or body, or mounted on the body, combined with other transmitters within a product, or embedded in garments. The device categories covered include but are not limited to mobile telephones, radio transmitters in personal computers, and desktop and laptop devices. The applicable frequency range is from 6 GHz to 10 GHz. This document specifies: conversion of the psSAR to the psAPD (Clause 6); uncertainty estimation (Clause 7); reporting requirements (Clause 8); methods of validation and system check (Annex C) The measurement and computational standards IEC/IEEE 63195-1:2022 [1]1 and IEC/IEEE 63195-2:2022 [2] for incident power density (IPD) cover the frequency range from 6 GHz to 300 GHz. Hence there is a frequency overlap from 6 GHz to 10 GHz between this document on APD and the IEC/IEEE standards addressing IPD. The committee was aware of this fact and opted for enhanced flexibility by providing methods for basic restriction metric APD in addition to reference level metric IPD. ___________ 1 Numbers in square brackets refer to the Bibliography.
Scope: This document specifies a conversion method for the assessment of the peak spatial-average absorbed power density (psAPD) in the human head and body due to exposure to radio frequency (RF) electromagnetic fields (EMF) from wireless communication devices, with a specified conversion uncertainty. This conversion method is based on specific absorption rate (SAR) values and is specified with the objective to yield conservative and reproducible absorbed power density values of the exposure for a significant majority of the population during the use of hand-held, body-worn or any other RF transmitting communication devices that can operate in close proximity to a human head or body. This conversion method applies for devices that can feature single or multiple transmitters and/or antennas and can be operated with their radiating structure(s) at distances up to 200 mm from a human head or body. The conversion method of this document can be employed to determine conformity with applicable absorbed power density or epithelial power density limits, such as those defined in ICNIRP guidelines 2020 [3] and IEEE Std C95.1™-2019 [4], of different types of RF transmitting communication devices being used in close proximity to the head and body. The assessment of psAPD is based on the conversion of the peak spatial-average specific absorption rate (psSAR) values assessed according to applicable international standards. The applicable frequency range of the conversion method of this document is 6 GHz to 10 GHz. NOTE Applicable international standards for the assessment of the psSAR are those accepted by the local regulatory body or specified in the CENELEC product standards. Such international standards include, e.g. IEC/IEEE 62209-1528 and IEC 62209-3 [5] for measurement methods, and IEC/IEEE 62704-1 [6] and IEC/IEEE 62704-4 [7] for computational methods. The frequency range of [5], [6] and [7] is limited up to 6 GHz. While the applicability of the methods of [5] for the frequency range of this document may need further verification, the numerical standards [6] and [7].may be applied for frequencies up to 10 GHz. The categories of RF transmitting communication devices covered in
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- Introduction