Medical electrical equipment – Medical electron accelerators – Guidelines for functional performance characteristics

Introduction: The guidelines given in this report are recommendations both to manufacturers and to USERS. They provide guidance to MANUFACTURERS on the needs of USERS in respect of the performance of ELECTRON ACCELERATORS and they provide guidance to USERS wishing to check the manufacturer's declared performance characteristics, to carry out acceptance tests and to check periodically the performance throughout the life of the equipment. IEC 60601-1 1) is a general standard for the safety of medical electrical equipment. It is supplemented by IEC 60601-2-1, a standard which lays down particular requirements for MEDICAL ELECTRON ACCELERATORS in the range of 1 MeV to 50 MeV. In addition, IEC 60976 second edition has been issued as a disclosure standard. It standardizes methods of declaring the MEDICAL ELECTRON ACCELERATOR functional performance characteristics. It standardizes the type test conditions and type test methods to which manufacturers' declared values of functional performance relate. A format for the presentation of functional performance values is contained in IEC 60976. It is repeated herein as 3.1, with the addition of a set of suggested values which reflects the need for precision in RADIOTHERAPY and the knowledge of what is reliably achievable technically. A corresponding rationale for the suggested values is presented in 3.2. In order to check whether each individual machine at the time of installation performs in a manner consistent with the set of functional performance va

Scope: This technical report applies to medical ELECTRON ACCELERATORS when used, for therapy purposes, in human medical practice. This technical report applies to medical ELECTRON ACCELERATORS which deliver a RADIATION BEAM of either X-RADIATION or ELECTRON RADIATION with NOMINAL ENERGIES in the range 1 MeV to 50 MeV at maximum ABSORBED DOSE RATES between 0,001 Gy s–1 and 1 Gy s–1 at 1 m from the RADIATION SOURCE and at NORMAL TREATMENT DISTANCES between 50 cm and 200 cm from the RADIATION SOURCE.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • Introduction
  • Introduction
  • Introduction